Necessary tools
Phillips screwdriver No. 1, 2
Hex key wrench; width across flats: 2 mm / 2.5mm / 4mm)
Hammer, Socket wrench (13mm, 17mm)
Precaution for Installation
(1) For safety in operation as well stability of the light source,
the importance of proper ceiling structure can not be
overemphasized. The ceiling structure capable of supporting
220lb (100kg) dead weight is requires.
(2) Be sure request specialized electric construction person
accompanied by indoor electric wiring work.
(1) Installation of Ceiling
1. Lead out the power supply cable (for indoor wiring
0.75m/m x 2 wires power cable or mode) from the
ceiling as necessary length (Approx.60cm) where the
ceiling light is mounted.
2. Secure flange base to the ceiling referring to below
figure.
Refer to "Flange base template" (20 page) for the flange base
fixing hole dimensions.
Flange
base
Flat washer
(M10, plated)
Spring washer
(M10, plated)
Ccoach bolt
(M9 x 100, plated)
Square timber
(Hard wood more
than 105mm)
Wood Ceiling
Steel Frame Ceiling
Flat washer
(M8, plated)
Spring washer
(M8, plated)
Hex bolt
(M8 x 50, plated)
Concrete Ceiling
Hex bolt
(M8 x 50, plated)
Flat washer
(M8, plated)
Spring washer
(M8, plated)
M8 Anchor nut
(Embedded)
3 Installation
Coach bolt
(M9 x 100, plated)
Hex bolt
(M8 x 50, Plated)
Hex bolt (M8 x 50, plated) /
M8 Anchor nut
Wood
Steel Frame
Concrete
Ceiling material
Prepared hole
diameter (mm)
Fixing bolt
M8 (Embedded Anchor nut)
φ
5
φ
10
3-2-2 AL-D102G