6 6
THIS IS AN UNCONTROLLED DOCUMENT.
THIS ELECTRONIC DOCUMENT MAY HAVE BEEN SUPERCEDED.
THE MOST CURRENT DOCUMENT INFORMATION IS AVAILABLE
FROM YOUR BELL HELICOPTER TEXTRON REPRESENTATIVE.
PRODUCT DATA
JANUARY 2003
“C/FL L QUILL” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
in the transmission left hand quill chip
detector circuit. This caution appears below
the xmsn oil temp/pressure vertical display
or as “XMSN C/FL” in the W/C/A window
when on the secondary screen page 2.
“C/FL R QUILL” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
in the transmission right hand quill chip
detector circuit. This caution appears below
the xmsn oil temp/pressure vertical display
or as “XMSN C/FL” in the W/C/A window
when on the secondary screen page 2.
“C/FL COLL GR” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
in the transmission planetary chip detector
circuit. This caution appears below the
xmsn oil temp/pressure vertical display or
as “XMSN C/FL” in the W/C/A window when
on the secondary screen page 2.
“C/FL SUMP PMP” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
i n t h e t r a n s m i s s i o n s u m p p u m p c h i p
detector circuit. This caution appears below
the xmsn oil temp/pressure vertical display
or as “XMSN C/FL” in the W/C/A window
when on the secondary screen page 2.
“C/FL TAIL RTR” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
in the tail rotor chip detector circuit. This
caution appears below the xmsn oil temp/
pressure vertical display or as “XMSN C/
F L ” i n t h e W / C / A w i n d o w w h e n o n t h e
secondary screen page 2.
This amber caution appears when a faulty
or unreliable D.C. power source from the
e n g i n e 1 m o u n t e d s t a r t e r / g e n e r a t o r i s
detected by the No.1 voltage regulator.
This caution uses the generator 1 voltmeter/
ammeter label as the annunciator by turning
it amber and flashing or as “1 Gen” in the
W/C/A window when on page 1.
When both generators are failed, the amber
caution changes to red warning.
“C/FL PLTRY GR” or “XMSN C/FL”
This caution appears when a chip detection
failure has been monitored by the CDPU
in the transmission collector gear chip
detector circuit. This caution appears below
the xmsn oil temp/pressure vertical display
or as “XMSN C/FL” in the W/C/A window
when on the secondary screen page 2.
“GEN” or “1 GEN” (Generator 1)
This caution appears when the CDPU fails.
This caution appears only into the W/C/A
window.
“CDPU”
Содержание BELL 430