background image

Product Number: QG0014-01 Revision: A0; Date: 4/29/13

3

Alarm. This LED is normally off, but turns red when an 
alarm condition is present in the controller. It is possible 
for each controller in a dual-controller frame to show an 
alarm.

The ‘Force Active’ button (backlit, white) allows you to cause 
the stand-by system controller (in a dual-controller frame) to 
become the active controller. When the controller becomes 
active, its active LED turns on and the active LED of the other 
controller turns off. 

Power Supplies

Both of the frame’s power supply modules accept from 100 to 
240 VAC, 47–63 Hz, automatically sensing the line voltage 
and frequency. 
The NV920 frame has two power LEDs. One LED, labeled 
‘Power’ at the front of the frame, indicates the presence of 
power. The other power LED (‘PS Alarm’) is off under normal 
circumstances, but turns red and blinks when one of the 
power supplies is missing or faulty. 
When one of the power supplies is removed (or fails), the 
frame emits an audible alarm (a continuous tone). The frame 
has a red button (at the rear) near the power supplies that 
turns off the alarm. 

This QuickStart Guide

The purpose of this document is to guide you through the 
physical installation of the NV920 frame, the installation of 
configuration software, and the initial setup of the software 
so that you can build configurations and read from and write 
to your system controller(s).
NV9000-SE Utilities is the primary tool for configuration. 

NV9000-SE Utilities

NV9000-SE Utilities is software that is required for the config-
uration and management of the NV920 control system. It is 
available on the SB0033 CD in this shipment. 
After you have obtained NV9000-SE Utilities, you can install 
it on any PC.

Control Panels

Control panels allow operators to setup and execute “takes” 
(routes) between source devices and destination devices. 

Physical

 control panels are separate hardware units that con-

nect to the system controller. 

Virtual

 control panels are soft-

ware applications that emulate physical control panels and 
run on any PC (or Mac) connected, through Ethernet, to the 
system controller. 
For more information on control panels, obtain the appropri-
ate control panel user’s guide from the Miranda website. Con-
tact Miranda customer service for assistance.

Master Control

Master Control is a name given to an optional subsystem that 
allows operators to transition program output from one 
source to another with real-time effects such as cross-fades, 
keyer and logo overlays, squeezeback, and audio overs. 
For more information, either visit the Miranda website or 
contact Miranda customer service.

System Controller Redundancy

A redundant system includes 2 system controllers. If one sys-
tem controller fails, the control system immediately switches 
to the other controller. 
The two system controllers of a dual-controller NV920 com-
municate with each other through an internal Ethernet link. 
The stand-by system controller queries the active system con-
troller frequently through the internal link. If the query and 
response mechanism fails, the stand-by controller presumes 
that the active controller is no longer functioning properly 
and takes over the role of active controller.

Installation

Setting up the NV920 system controller requires several steps: 
Part 1

Mount the NV920 in a rack, insert its power sup-
plies, system controllers, and connect power. 

Part 2

Make physical network and I/O connections. 

Part 3

Install NV9000-SE Utilities software on your config-
uration PC(s).

Part 4

Perform initial setup in NV9000-SE Utilities.

Networks require an Ethernet switch and CAT5 Ethernet 
cable. (Miranda’s EC9415

 

 

a 24-port Ethernet switch

 

 

is 

suitable.) 

Part 1: Mount the Controller and Connect Power

The 1RU NV920 frame fits in a standard 19

 (482.6 mm) rack. 

When placing the NV920 frame in your facility, keep in mind 
that the NV920 needs a minimum of 6

 (15

 

cm) of unre-

stricted air flow at the front and rear for cooling and needs an 
adequate amount of space at the sides for air intake. 
The NV920 frame (with power supplies and system control-
lers installed) extends 19.9

 toward the rear of the rack and 

projects about 1.2

 in front of the rack. 

The removable power supply modules are about 10.5

 deep. 

So you will need about 12

 clearance at the rear to remove and 

insert power supply modules. 
The NV920 frame is heavy and requires mounting hardware 
at the rear of the frame. See Figure 4. 

Содержание Miranda NV920

Страница 1: ...e as listed on this page NV915 Each NV915 system controller is 1RU has one disk drive 2 Ethernet ports and no expansion ports One of the Ether net port is available to support routers and control pane...

Страница 2: ...g and receiving respec tively There are also cooling fans at the rear of each system control ler The rear of the NV920 frame has grill openings that vent the exhaust from the fans Each system controll...

Страница 3: ...ller For more information on control panels obtain the appropri ate control panel user s guide from the Miranda website Con tact Miranda customer service for assistance Master Control Master Control i...

Страница 4: ...pting system data Before disconnecting power press the Power Down to Remove button of each system controller of the frame Wait for the system con trollers LEDs to turn off Then disconnect power Part 2...

Страница 5: ...ams a redundant system that uses NVNET 1 for a network of panels and routers NVNET 2 for a master control network NVNET 3 for configuration and monitoring If your sys tem has a single system controlle...

Страница 6: ...n any PC connected over Ether net to the system controller NV9000 SE Utilities can also be used offline to create con figurations that you can transport and use at different loca tions S Note that NV9...

Страница 7: ...em controller s S We invite you to copy the sample configuration from the installa tion CD It is instructive You can also use the sample configura tion as a starting point and modify it to represent t...

Страница 8: ...oes not open Yellow icons represent system with warning level errors Red icons indicate severe errors or disconnected systems There are two remaining steps Click Write configuration to your system Wai...

Страница 9: ...onfiguration to your system in the system management page Click Start or Restart 4 After about 30 seconds the controller should be running with the sample configuration The sample configuration has ve...

Страница 10: ...twork configuration windows 6 Log out 7 Repeat these steps for the other system controller if there is one Installing NV9000 Tools on Your PC The system controller comes with several useful applicatio...

Страница 11: ...shown in Figure 2 on page 2 NV920 Specifications System Controller Specifications Contact Information Contact Miranda if you need information about NVISION router control systems or third party automa...