Installation RS20/22/30/32/40
Release 03 06/2013
9
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the
conductors, the temperature specification of the selected cable and
cable entries shall be in compliance with the actual measured
temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 40 %.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
DIP switches shall be switched exclusively in dead-voltage state.
The USB port shall remain disconnected.
Housing
Only technicians authorized by the manufacturer are permitted to open
the housing.
The housing is grounded via the separate ground screw on the bottom left
of the front panel.
WARNING
ELECTRIC SHOCK
Never insert sharp objects (small screwdrivers, wires, etc.) into the inside of
the device.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for the supply voltage or the signal contact, and do not
touch the terminals!
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
CAUTION
OVERHEATING OF THE DEVICE
When installing the device, ensure that the ventilation slots are not covered.
Make sure there is at least 10 cm (3.94 in) of space.
Failure to follow these instructions can result in injury or equipment
damage.