52
Installation RS20/22/30/32/40
Release 03 06/2013
2.3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Configuration via V.24 connection
Configuration using the HiDiscovery protocol
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP (Option 82)
Configuration using AutoConfiguration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual on the CD/DVD.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
V.24 data rate: 9,600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s, full duplex
All other ports: autonegotiation
Ring Manager disabled (DIP switch RM and stand-by: ON)
Stand-by coupling disabled (DIP switch RM and stand-by: ON)
Port 4 = control port, port 3 = coupling port for red. Ring coupling
Rapid Spanning Tree enabled
USB interface
The USB socket is an interface for the local connection of an
AutoConfiguration Adapter ACA21-USB. It is used for saving/loading the
configuration data and diagnostic information, and for loading the
software.
LS - link status (green LED)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 time a period) Port is switched to stand-by.
Flashing green (3 times a
period)
Port is switched off.
DA - data (yellow LED)
Not glowing
No data reception at corresponding port
Flashing yellow
Data reception at corresponding port