20
Installation RS20/22/30/32/40
Release 03 06/2013
Additional examples of devices with 3 or 4 uplink ports:
RS20-0900
NNM4
TDAE for RS20 with 3 uplink ports (ST)
NN
: 2 × Multimode FX, ST, 100 Mbit/s (ports 1 and 2)
M4
: 1 × Multimode FX, ST, 100 Mbit/s (port 3)
RS30-2402
OOZZ
TDAP for RS30 with 4 uplink ports (SFP)
OO
: 2 × SFP slot, 1000 Mbit/s (ports 1 and 2)
ZZ
: 2 × SFP slot, 100 Mbit/s (ports 3 und 4)
Example of device with Power over Ethernet:
RS32-0802
O6T1
S
P
AP for RS32 with 2 uplink ports and PoE
O6
: 1 × SFP slot, 1000 Mbit/s (port 1)
T1
: 1 × twisted pair TX, RJ45, 1000 Mbit/s (port 2)
P
: Voltage range 47 V DC to 52 V DC (PoE)
1.1.2
Combination options for RS40
The product designation of your device is made from combining the desired
product characteristics in accordance with the following table. The
corresponding short designation is in column 3.
Item
Characteristic
Ident. Property
1 to 4
Product
RS40 Rail Switch with gigabit ports
5
- (hyphen)
-
6 and 7
Number of 10/100
Mbit/s ports
00
0 × 10/100 Mbit/s Ethernet
8 and 9
Number of 1000
Mbit/s ports
09
9 × 1000 Mbit/s Ethernet
10 and 11
1st + 2nd uplink port CC
2 × combo port multirate (SFP slot: 100/1000 Mbit/s,
alternatively twisted pair RJ45 socket: 10/100/1000
Mbit/s)
12 and 13
3rd + 4th uplink port CC
2 × combo port multirate (SFP slot: 100/1000 Mbit/s,
alternatively twisted pair RJ45 socket: 10/100/1000
Mbit/s)
14
Temperature range S
Standard 0 °C to +60 °C
T
Extended -40 °C to +70 °C
E
Extended -40 °C to +70 °C, conformal coating
15
Voltage range
D
9.6 V DC to 60 V DC or 18 V AC to
30 V AC
16
Certification
A
CE, UL 508, ISA 12.12.01 (UL 1604)
H
CE, UL, 508, GL, railway (along track), sub station.
Pending: ISA 12.12.01 (UL 1604).
B
CE, UL, 508, GL, railway (along track), sub station.
Pending: ISA 12.12.01 (UL 1604), Hazardous
Location (ATEX).
17
Software variant
E
Enhanced
P
Professional
Table 5:
Combination options for the device variants of the RS40