62
Installation RS20/22/30/32/40
Release 03 06/2013
Scope of delivery
Order numbers/product description
You will find order numbers and product designations for the RS20/30 and
RS40 in the Combination Options section.
See “Combination options for RS20/30” on page 17.See “Combination
options for RS40” on page 20.
Device name
Device model
Maximum
power
consumption
Power output
2 uplink ports:
RS22-0800...
2xTX port
70.9 W
31.8 Btu (IT)/h
RS22-0800...
1xFX port, 1xTX port
72.1 W
35.9 Btu (IT)/h
RS22-0800...
2xFX port
73.3 W
40.0 Btu (IT)/h
RS22-1600...
2xTX port
75.0 W
45.8 Btu (IT)/h
RS22-1600...
1xFX port, 1xTX port
76.2 W
49.9 Btu (IT)/h
RS22-1600...
2xFX port
77.4 W
54.0 Btu (IT)/h
RS22-2400-...
2xTX port
77.7 W
55.0 Btu (IT)/h
RS22-2400-...
1xFX port, 1xTX port
78.9 W
59.1 Btu (IT)/h
RS22-2400-...
2xFX port
80.1 W
66.6 Btu (IT)/h
RS32-0802-...
2xTX port
74.5 W
44.1 Btu (IT)/h
RS32-0802-...
1xFX port, 1xTX port
74.2 W
43.1 Btu (IT)/h
RS32-0802-...
2xFX port
73.9 W
42.1 Btu (IT)/h
RS32-1602-...
2xTX port
78.6 W
58.1 Btu (IT)/h
RS32-1602-...
1xFX port, 1xTX port
78.3 W
57.1 Btu (IT)/h
RS32-1602-...
2xFX port
78.0 W
56.1 Btu (IT)/h
RS32-2402-...
2xTX port
81.3 W
67.3 Btu (IT)/h
RS32-2402-...
1xFX port, 1xTX port
81.0 W
66.3 Btu (IT)/h
RS32-2402-...
2xFX port
80.7 W
65.3 Btu (IT)/h
3 uplink ports:
RS22-0900-...
3xFX port
75.2 W
46.5 Btu (IT)/h
RS22-1700-...
3xFX port
79.3 W
60.4 Btu (IT)/h
RS22-2500-...
3xFX port
82.0 W
69.7 Btu (IT)/h
4 uplink ports:
RS32-0802-...
4xFX port
78.3 W
57.0 Btu (IT)/h
RS32-1602-...
4xFX port
82.4 W
71.0 Btu (IT)/h
RS32-2402-...
4xFX port
85.1 W
80.2 Btu (IT)/h
Table 21: Power consumption/power output RS22/RS32 with 4 x Class0 PD
(powered device)
Device
Scope of delivery
RS20-..., RS30-..., RS40-...,
RS22-... or RS32-...
Device
Terminal block for supply voltage and signal contact
Installation user manual and CD-ROM
RS22-16..., RS22-17...,
RS22-24..., RS22-25...
Additionally: ferrite with key
Содержание Hirschmann RPS90/48V HV
Страница 66: ......