34
Installation RS20/22/30/32/40
Release 03 06/2013
2.1.4
Adjust DIP switch settings
The 2-pin DIP switch on the front panel of the device gives you the following
options:
Figure 15: 2-pin DIP switch
Delivery state: both DIP switches “ON”.
Before starting operation of the device, check whether the default settings
of the DIP switch correspond to your requirements.
2.1.5
RS20/RS30/RS40: supply voltage and
signal contact
The supply voltage and the signal contact are connected via a 6-pin terminal
block with a snap lock.
Caution!
Note the safety instructions
“Safety instructions” on page 4
and only
connect a supply voltage that corresponds to the type plate of your
device. Make sure that the contact load capability of the signal
contact is not exceeded
.
Supply voltage for RS20/RS30/RS40
Redundant power supplies can be used. Both inputs are uncoupled.
There is no distributed load. With redundant supply, the power supply unit
supplies the device only with the higher output voltage. The supply
voltage is electrically isolated from the housing.
See “Insulation voltage” in section
.
You can choose between DC or AC voltage when connecting the supply
voltage. You use the +24V and 0V pins to connect the AC voltage
(see
figure 16)
.
Switch
RM
position
Switch
stand-by
position
Ring
redun-
dancy
Coup-
ling
switch
Ring
Manag
er
Coupli
ng
Manag
er
Ring
port
Control
port
Coup
ling
port
Software
configuration
OFF
OFF
on
on
off
off
1 + 2
ON
OFF
on
on
on
off
1 + 2
OFF
ON
on
on
off
on
1 + 2
3
4
ON
ON
SW config. has
priority over
DIP switch
configuration
RM
Stand by
ON