50
Installation RS20/22/30/32/40
Release 03 06/2013
100 MBit/s F/O ports enable the connection of terminal devices or
independent network segments in compliance with the IEEE 802.3
100BASE-FX standard.
These ports support:
Full or half duplex mode
Default setting: Full duplex
Note:
Make sure that the LH ports are only connected with LH ports, SM
ports are only connected with SM ports, and MM ports only with MM ports.
1 Gbit/s F/O connection
These ports are SFP slots.
1000 Mbit/s F/O ports enable the connection of terminal devices or
independent network segments according to the IEEE 802.3 1000BASE-
SX/1000BASE-LX standard.
These ports support:
Autonegotiation
Note:
Make sure that the LH ports are only connected with LH ports, SX
ports are only connected with SX ports, and LX ports only with LX ports.
Note:
In device variants RS30-...02OOZZ... and RS32-...02OOZZ... (four
uplink ports with SFP slot), Gigabit-ETHERNET-SFP transceivers or
Fast-ETHERNET-SFP transceivers can be mounted at the two top ports,
and Fast-ETHERNET-SFP transceivers can be mounted at the two
bottom ports
In device variants RS40-..., Gigabit-ETHERNET-SFP transceivers or
Fast-ETHERNET-SFP transceivers can be mounted at the combo ports
.
2.2
Display elements
After the operating voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up. The process takes around 60 seconds.
Device state
These LEDs provide information about conditions which affect the
operation of the whole device.
Содержание Hirschmann RPS90/48V HV