background image

128

Kaleido-IP/Kaleido-X16 Cascade Step-by-Step Configuration

Physical Installation

To interconnect a Kaleido-IP and a Kaleido-X16 into a cascade

1  Connect one of the Kaleido-IP’s DisplayPort outputs to a DVI input on the Kaleido-X16.

2 In the case of a cascade room with two output heads, connect the second DisplayPort 

output on the Kaleido-IP to the second DVI input on the Kaleido-X16.

3 Connect the appropriate HDMI outputs on the Kaleido-X16 to one or two monitor wall 

displays, depending on the multiviewer model (dual or single) and on your specific 
purposes.

Note:

Although nothing prevents you from connecting any DisplayPort 

output to any DVI input, the recommended practice is to choose the most 
logical signal path, by connecting DP1 to DVI IN 1, and DP2 to DVI IN 2. 
Configuring your cascade system in XEdit will then be straightforward.

Содержание Grass Valley KALEIDO-X16

Страница 1: ...Installation Service Manual M869 9902 117 2018 03 02 KALEIDO X16 SUPER SILENT 16 INPUT DUAL OUTPUT MULTIVIEWER...

Страница 2: ...Multiviewers to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanica...

Страница 3: ...r to making any other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that...

Страница 4: ...id or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and components while power is on High lea...

Страница 5: ...ipment Electrostatic Discharge ESD Protection Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affec...

Страница 6: ...ence dans le texte doit tre remplac par un fusible du m me calibre Identifie une borne de mise la terre de protection Il faut relier cette borne la terre avant d effectuer toute autre connexion l quip...

Страница 7: ...endommager les connecteurs Coupez l alimentation avant de nettoyer l quipement Ne pas utiliser de nettoyants liquides ou en a rosol Utilisez uniquement un chiffon humide Des tensions dangereuses peuve...

Страница 8: ...parations autres que celles qui sont d crites dans le pr sent manuel sauf si vous tes qualifi pour le faire Confiez les r parations un technicien qualifi La maintenance doit se r aliser dans un milieu...

Страница 9: ...the requirements of the following standards for safety of information technology equipment CSA C22 2 No 60950 1 07 2nd Edition UL 60950 1 2nd Edition EN 60950 1 2006 ITE IEC 60950 1 2005 2nd Edition...

Страница 10: ...bstance contained in all of the homogeneous materials for this part is below the limit requirement in GB T 26572 2011 X GB T 26572 2011 X Indicates that this toxic or hazardous substance contained in...

Страница 11: ...rials 21 Physical Interface 22 Frame Description 22 Mechanical Installation 23 Mounting the Kaleido X16 in a Rack 23 Ventilation 23 CompactFlash 25 3 Multiviewer Cabling 27 Cabling Diagram 27 Port Ava...

Страница 12: ...Ways to Access XAdmin 64 Opening XAdmin from a Browser 64 Opening XAdmin from XEdit 65 Registering your Multiviewer s Security Credentials with your Browser 65 Enabling the Compatibility View in Inter...

Страница 13: ...113 Troubleshooting Common Issues 114 Disposal and Recycling Information 116 7 Configuring a Kaleido X16 Cascade 117 Introduction 117 Physical Installation 117 Interconnecting the Multiviewers 117 Co...

Страница 14: ...puts 143 Audio I O 144 Control 145 Frame 146 Multiviewer Integration with other Systems and Equipment 146 Optional Drivers for Controlling Routing Devices from the Multiviewer 146 Optional Drivers for...

Страница 15: ...t software drivers and sample databases from the Downloads section of the Grass Valley s website www grassvalley com dl multiviewers Document Number Title M770 2800 Kaleido Software User s Manual M770...

Страница 16: ...on is set to automatically detect the resolution of the associated display If this information is not available it will fall back to 1280 1024 60 Hz Refer to the Kaleido Software User s Manual for ins...

Страница 17: ...22 When downgrading this multiviewer certain other requirements and limitations may be in effect see Upgrading the Multiviewer on page 104 for more information To upgrade a multiviewer see Upgrading t...

Страница 18: ...tem overview Available Models The Kaleido X16 system is available in two model types a single head model Kaleido X16 S and a dual head model Kaleido X16 D Throughout this manual Kaleido X16 refers to...

Страница 19: ...RCP 200 multi function remote control panel Audio Bridge Terminal ABT Functional block diagrams The following diagram shows a basic Kaleido X16 system configuration with a single Kaleido X16 feeding...

Страница 20: ...20 Overview Functional block diagrams...

Страница 21: ...r power supply Kaleido Multiviewers Documentation Resource Guide One mouse Four serial port adapters one with straight wiring and one with crossover wiring for each of the two RS 422 ports on your mul...

Страница 22: ...ocumentation Resource Guide and some related documents e g welcome letters warranty cards are distributed in printed form You can obtain the latest version of the Kaleido X User s Manual and Installat...

Страница 23: ...ed by the brackets 2 Position the Kaleido X16 frame at the designated location within the rack and secure the front of the frame to the rack by using suitable screws and washers not included Ventilati...

Страница 24: ...Each PSU draws air through the frame s front grille through the PSU then out to the closest rear fan to be exhausted out the side of the frame see diagrams above and below Air Filter Cooling air drawn...

Страница 25: ...influence airflow inside the frame altitude and airflow obstruction on the sides of the unit CompactFlash In order to boot the CPU you must ensure the appropriate CompactFlash CF card is properly inse...

Страница 26: ...26 Installation CompactFlash...

Страница 27: ...ido X16 cabling diagram Port Availability The Kaleido X16 offers a wide variety of ports for incoming and outgoing signals However with a view towards future expansion the following ports exist but th...

Страница 28: ...eo inputs 1 to 16 MV OUT 1 2 HDMI HDMI output including embedded audio for each head SDI OUT 1 2 BNC Serial digital HD output signal for monitoring purposes REF BNC Reference signal to genlock the mul...

Страница 29: ...for specification details Mosaic Outputs HDMI Outputs There is one progressive scan HDMI output for each output head MV OUT 1 MV OUT 2 See HDMI Outputs on page 141 for specification details The HDMI c...

Страница 30: ...50 00 59 94 1280 768 WXGA 50 00 59 94 1280 1024 SXGA 50 00 59 94 1280 1024 Barco 59 94 1360 768 NEC 50 00 59 94 1480 1200 Christie 50 00 59 94 1600 1200 UXGA 50 00 59 94 1920 1080 Baycat 50 00 59 94 1...

Страница 31: ...information about Routers and the Kaleido X16 see the Routers chapter of the Kaleido Software User s Manual See Related Documentation on page 15 Audio I O The Kaleido X16 supports audio monitoring thr...

Страница 32: ...e Kaleido X16 D is as follows Bottom row Center row Top row 19 GND 10 AES Out 1 1 AES Out 1 20 GND 11 AES Out 2 2 AES Out 2 21 GND 12 GND 3 GND 22 GND 13 Analog Left Out 1 4 Analog Left Out 1 23 GND 1...

Страница 33: ...o Monitoring Color in the Calibrating the Kaleido X chapter of the Kaleido Software User s Manual See Related Documentation on page 15 Control The connectors located in the middle of the rear connecto...

Страница 34: ...connector is as follows Bottom row Middle row Top row Pin Description Pin Description Pin Description 31 GND 16 GPI Output N 1 1 GPI Output P 1 32 GPI Output N 2 17 GPI Output P 2 2 GPI Output N 3 33...

Страница 35: ...sing positive and negative terminal connections Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position Negative pins labelled with an...

Страница 36: ...output events see Triggering GPI Output Events in the Operation of the Monitor Wall chapter of the Kaleido Software User s Manual calibrating GPI lines see Calibrating GPI Lines in the Calibrating the...

Страница 37: ...One USB connector on the front of the frame Commissioning the Multiviewer To make the multiviewer operational first power it up and then interconnect the multiviewer with its associated equipment Pow...

Страница 38: ...n the right side of the rear connector panel as you face the rear of the frame This should be on the same side of the frame as the one PSU you have installed If you do not do this your system cannot d...

Страница 39: ...the Output Resolution below for detailed instructions 3 Connect one or more video sources to your multiviewer s inputs see Cabling Diagram on page 27 4 Check the LEDs in the Kaleido X16 frame Make su...

Страница 40: ...o X16 2 Right click anywhere on the monitor wall point to Monitor wall if you clicked a monitor and then click Display resolution The Display Resolution window appears If you would like the system to...

Страница 41: ...background and then click Display Resolution on the menu 2 Select the Use detected monitor resolution check box 3 Click OK Notes The monitor EDID auto detection feature is enabled by default in order...

Страница 42: ...42 Multiviewer Cabling Enabling EDID Auto Detection from the Monitor Wall...

Страница 43: ...on page 15 A GPI interface allows remote layout selection See Loading a Layout on page 98 The output resolution of the card can be controlled automatically through the EDID interface with the display...

Страница 44: ...ps full duplex LED LED Status Green Blinking green Red Blinking red Yellow Blinking yellow Off CPU Normal operation Application booting Error Live Update OS Booting N A Front cover is closed CPF Activ...

Страница 45: ...o X16 multiviewer to join a TCP IP network it must be configured with an IP address a network mask a gateway and a system name The IP address system name and other parameters can be set via a control...

Страница 46: ...r generates a low to moderate amount of client to server data traffic and therefore has a minimal bandwidth impact on a network TCP UDP Port Usage The various Kaleido X16 communication protocols requi...

Страница 47: ...connection 13100 TCP Used for calibration data from XEdit 5120 RCP2 TCP Used to listen for Kaleido Software discovery packets 10000 TCP For RCP2 protocol 10001 TCP For RCP2 protocol 5120 UDP On multic...

Страница 48: ...TCP Responsible for discovery and communications between devices services on a network 32768 65535 Java RMI TCP Remote Method Invocation client server communication Dynamic Allocation of ports Require...

Страница 49: ...vices that use the TSL UMD version 5 0 protocol Port Used for Notes 2000 TCP Used to control the multiviewer s internal router via the SAM Snell Pro Bel SW P 02 protocol 4381 TCP Used to control the m...

Страница 50: ...er in the advent that such a change was made by mistake or that it as been forced for some reason you will have to repair the broken cluster see Repairing a Cluster System in the Kaleido Software User...

Страница 51: ...ettings directly on the multiviewer or you can work locally on the computer and then export your changes to the multiviewer If you have only one multiviewer or if you have more than one but you intend...

Страница 52: ...n the address bar The multiviewer s home page appears 2 Click the XEdit button The browser prompts you to save an executable file to your hard drive Kaleido windows32 online exe1 This file is an onlin...

Страница 53: ...10 shortcuts are added to your desktop and to the Start menu under All Programs If you have Windows 8 1 or Windows 8 XEdit will appear on your desktop in the Apps view with all the other applications...

Страница 54: ...ase a message will appear to confirm the font update and instruct you to restart the application Click OK to continue and then open XEdit again by using the shortcut on your desktop in your Apps view...

Страница 55: ...on page 56 If you have been using XEdit versions earlier than 7 20 you may want to uninstall them by clearing the Java cache on your PC or laptop See Uninstalling XEdit Version 7 11 or Earlier on page...

Страница 56: ...ars 4 Click Uninstall This removes XEdit including all shortcuts launchers and other elements that were installed with it from your system Uninstalling XEdit Version 7 11 or Earlier To uninstall XEdit...

Страница 57: ...s may allow you to run the file directly Depending on your browser s security features warnings may appear which you may safely dismiss 3 Unless your browser let you run the file and you chose to do s...

Страница 58: ...thin your multiviewer system in addition to the KX Router logical router 4 In Router Control click the router you want to control and then click Open Depending on your Windows Firewall settings a secu...

Страница 59: ...iew Start screen see page 57 or from the Start menu Whenever you install a new version of the Kaleido Software on the multiviewer the next time you open Router Control your installed copy of the appli...

Страница 60: ...wser prompts you to save an executable file to your hard drive Kaleido__SignalPathViewer windows32 online exe1 This file is an online installer which will download Signal Path Viewer from your multivi...

Страница 61: ...or Windows 8 Signal Path Viewer will appear on your desktop in the Apps view with all the other installed applications on your PC Windows 8 1 or in your Start screen Windows 8 Once the installation h...

Страница 62: ...k Uninstall Signal Path Viewer An uninstall screen appears 4 Click Uninstall Notes Once it has been installed from the multiviewer Signal Path Viewer remains on your PC or laptop and can be launched f...

Страница 63: ...with your PC Under this circumstance proceed as follows There is no compatibility problem if only the patch revision number is different between the Kaleido Software version on the multiviewer and the...

Страница 64: ...page 65 Internet Explorer users may also need to enable compatibility view see Enabling the Compatibility View in Internet Explorer on page 74 Opening XAdmin from a Browser To open XAdmin from a brows...

Страница 65: ...ation area on the left side of the page Registering your Multiviewer s Security Credentials with your Browser When you open your multiviewer s home page or try to access XAdmin your browser may report...

Страница 66: ...rity Credentials with your Browser To register your multiviewer s security credentials with Firefox 1 Click I understand the Risks at the bottom of the page The message expands 2 Click Add Exception 3...

Страница 67: ...without seeing the warning This will remain effective until the multiviewer s IP address is changed in which case you will need follow the procedure again Suppressing certificate error in Internet Exp...

Страница 68: ...68 System Configuration Registering your Multiviewer s Security Credentials with your Browser Internet Explorer s security warning Chrome s security warning...

Страница 69: ...xplorer 1 Click Continue to this website not recommended The address bar now indicates the certificate error 2 Click Certificate error 3 In Untrusted Certificate click View certificates 4 In Certifica...

Страница 70: ...ion Registering your Multiviewer s Security Credentials with your Browser 5 In Certificate Import Wizard click Next 6 In Certificate Import Wizard click Place all certificates in the following store a...

Страница 71: ...71 Kaleido X16 Hardware Description Installation Manual 7 In Select Certificate Store select Trusted Root Certification Authorities and then click OK 8 Back in Certificate Import Wizard click Next...

Страница 72: ...72 System Configuration Registering your Multiviewer s Security Credentials with your Browser 9 Click Finish A security warning appears...

Страница 73: ...n You should now be able to access XAdmin from your multiviewer home page without ever seeing the security warning again unless the multiviewer s IP address is changed in which case you will want to r...

Страница 74: ...n s Status and Options page 1 To enable the compatibility view for your multiviewer s XAdmin Web client Click the Compatibility View button at the end of your browser s address bar XAdmin s Status and...

Страница 75: ...modifying a multiviewer s system configuration Enabling XAdmin Access Control To enable access control in XAdmin 1 Open XAdmin See Opening XAdmin on page 63 2 Click Access control in the navigation a...

Страница 76: ...ess indicator appears momentarily followed by a confirmation message 7 Click OK The Log in to XAdmin page appears Other XAdmin sessions open against the same multiviewer are also redirected to the log...

Страница 77: ...New password and the Confirm boxes The password must contain between 6 and 20 alphanumeric characters or symbols 4 Click Save A confirmation message appears 5 Click OK to close the message window The...

Страница 78: ...cess control in the navigation area on the left side of the page The Access Control page appears 3 Click Disable access control A confirmation message appears 4 Click OK to close the message window an...

Страница 79: ...Path Viewer Double click the Signal Path Viewer shortcut on your desktop The application automatically connects to your multiviewer and the Signal Path Viewer panel appears Viewing a Multiviewer s Sta...

Страница 80: ...nter to an input signal status indicator to view the associated signal format 3 Click the arrow button at the end of a module s heading row to view more detailed information about this card or multivi...

Страница 81: ...Hardware and Software Options on page 94 Configuring a Multiviewer s IP Time and Date Settings with XAdmin To change your system s IP address and other parameters 1 Open XAdmin See Opening XAdmin on p...

Страница 82: ...tion frame or card IP addresses network mask and default gateway By default all network adapters are set to auto negotiate The connection speed and duplex mode will be set automatically based on the c...

Страница 83: ...e system immediately 11 Click OK If you have changed the multiviewer s IP address you will need to edit the XAdmin URL in your Web browser s address bar in order to log on to the multiviewer again Not...

Страница 84: ...the SELECT area rotate the leftmost control knob to select IP ADDRESS 5 Use the four control knobs in the CHANGE area to set the new address The current address is displayed in the CURRENT box for re...

Страница 85: ...creen Kaleido Multiviewer rooms are listed in the form multiviewer name room name If a room belongs to a cluster system its name appears once for each of the member multiviewers e g if two multiviewer...

Страница 86: ...itor wall control panel appears on the right hand screen with the ASSIGN CHANNEL category selected If a mouse is connected to the RCP 200 then after touching WALL MOUSE you should be able to see and m...

Страница 87: ...assign a source to a monitor located in a part of the layout that belongs to a different member of the cluster or cascade You only need to do this once for every multiviewer that is part of a cluster...

Страница 88: ...ic IP address 10 0 3 191 Assigning a static IP address to the Kaleido RCP2 To assign a static IP address to the Kaleido RCP2 1 Press and hold the ENTER button until the ESC button lights up to display...

Страница 89: ...key to move up in the list or the 8 key to move down the list 4 When the appropriate room name is highlighted press ENTER to accept the new selection 5 When prompted log on to the selected room See L...

Страница 90: ...procedure To log on to a Kaleido Multiviewer system from the Kaleido RCP2 1 Press the LOGIN key The following message will appear on the LCD display LOGIN Position Admin 2 Press ENTER to select Admin...

Страница 91: ...PC to Configure the ABT s Network Settings on page 93 configure the PC with the following network settings 3 Apply power to the Audio Bridge Terminal and make sure it is connected to the same switch...

Страница 92: ...ntation on page 15 Property Setting DHCP OFF Static IP address 10 0 3 190 Subnet mask 255 255 0 0 Default gateway 10 0 0 1 Notes The Kaleido X16 supports one ABT device You can achieve redundancy by c...

Страница 93: ...then press Enter 2 In the search box type adapter and then under Network and Sharing Center click View network connections 3 In Network Connections right click the network adapter you wish to configu...

Страница 94: ...ware options are enabled by entering a software key that has been sent to you once you have purchased the option The following tables list options that can be enabled via the XAdmin Status and Options...

Страница 95: ...Rotation license for Kaleido X16 D Dual router output KXS X16 RTR16X2 Dual router output option 1 frame SDI Monitoring Output KXS X16 HDM S SDI monitoring output for Kaleido X16 S KXS X16 HDM D SDI m...

Страница 96: ...Multiviewer input card you would need to locate the appropriate card in XAdmin s Status and Options page expand it and then locate the KXI 16 CC XDS option line 4 Click the Enable button A window appe...

Страница 97: ...System IP Address and Application Version To find the system IP address system name and application version 1 Connect a mouse to a USB connector either the USB at the front of the frame or one of the...

Страница 98: ...ashboard at the bottom right Enlarged view of dashboard Loading a Layout To load a layout on the monitor wall 1 Connect a mouse to the Kaleido RCP2 if available and log on to the Kaleido X16 from the...

Страница 99: ...you clicked a monitor and then click Load layout on the shortcut menu Monitor wall shortcut menu A layout browser appears on the displays associated with the current room 3 Select the layout you wish...

Страница 100: ...rred to as PSU A and the PSU on the right side is PSU B Power supply for the Kaleido X16 frame Access the power supplies by removing the front cover of the frame Viewed from the front of the frame the...

Страница 101: ...SU and pull the PSU out of the frame Installing a Power Supply To install a power supply 1 Position the power supply PSU in front of an empty power supply slot in front of the frame with the connector...

Страница 102: ...ratching vacuum the dust from the inner side of the cover 4 Turn the cover over and vacuum the outer side of it 5 Reinstall the cover onto the frame Generating a System Snapshot A system snapshot crea...

Страница 103: ...appears 3 Click system snapshot The system snapshot generation may take a few moments after which your browser prompts you to save the resulting compressed folder to your hard drive 4 Browse to the l...

Страница 104: ...ware version 5 22 or higher Ref KX 4751 The Internal router logical router is not supported anymore When the multiviewer s internal router is controlled from an external router control device or appli...

Страница 105: ...tation of virtual alarms has changed as of version 6 30 of the Kaleido Software If you are upgrading the multiviewer from a version prior to 6 30 then once the upgrade is completed it will be necessar...

Страница 106: ...alarm will be raised after 5 seconds In this example after the upgrade you should set the Set duration parameter to 15 seconds to maintain the same behavior It is recommended to review and note down...

Страница 107: ...see Verifying the Version Number on page 111 Preparing a USB Key To copy all files required for the upgrade to a USB key 1 Download the update files onto your PC s hard drive See Software and Firmwar...

Страница 108: ...tem file with the following format kxos 9 10_build_xxxx 4GB img The img file will be copied to the USB key This may take a few minutes When the copying process has finished a message appears 8 Click O...

Страница 109: ...nnect the mouse directly to a USB port on the multiviewer and then make sure you can move the pointer on the monitor wall See Troubleshooting with the Multiviewer s USB connector on page 113 for more...

Страница 110: ...o restart the system The multiviewer now restarts IMPORTANT To cancel the upgrade process you must click to ABORT within 30 seconds During the 30 second countdown period you may expect that removing t...

Страница 111: ...ll menu within composite monitor menu After a brief delay the dashboard appears at the bottom right corner of the monitor and the command Hide dashboard replaces Show dashboard on the menu Dashboard o...

Страница 112: ...ated for the Card revision attribute must be 0x4 or more Support for feeding a Kaleido X16 s HDMI output to an EdgeVision device requires version 5 30 or later A Kaleido X16 multiviewer that shipped w...

Страница 113: ...ear in the Status dashboard lower right corner and in the Upgrade dashboard lower left corner on the Monitor wall Status dashboard messages Message Description PSU A 12 V PSU A is absent overheating h...

Страница 114: ...in XAdmin for each card See Enabling Options on page 95 Valid licenses have a green dot Purchase and install a license for each card as required Contact Technical Support for more information and see...

Страница 115: ...me and exchange their positions within the frame before firmly reinserting the cards into the frame To RMA a defective card see Grass Valley Technical Support on page 152 Swapping around a Power Suppl...

Страница 116: ...safe handling practices Do not dispose of batteries in a fire as they may explode Batteries may explode if damaged or overheated Do not dispose of batteries as household waste Do not dismantle open or...

Страница 117: ...the last multiviewer which sends the resulting output to the monitor wall display Unlike the cluster whose purpose is to increase the number of output heads in a room the cascade increases the maximum...

Страница 118: ...ending on the multiviewer model dual or single and on your specific purposes Connecting the Displays Connect the available displays to the appropriate HDMI outputs on the last Kaleido X16 in the casca...

Страница 119: ...The multiviewers you wish to add to a cascade must have the Kaleido Software version 6 20 or later and all cascade members must have the same version of the software Each multiviewer you wish to add t...

Страница 120: ...ou wish to add are on the same subnet then you can select the multiviewer s IP address from the list Otherwise type the appropriate IP address in the box The multiviewer is added to the System list 4...

Страница 121: ...roperties pane its name appears in the Output head box In the case of a cascade with three multiviewers select the first multiviewer i e the one farthest from the monitor wall from the Layer 3 head fo...

Страница 122: ...er head 4 On the File menu click Save The updated room configuration is automatically propagated to the other multiviewers in the cascade Configuring Layouts for a Cascade Room Creating cascade layout...

Страница 123: ...is will replicate the proper room configuration to the other members of the cascade At the same time the layouts will also be updated on all multiviewers in the cascade Cascade Upgrade Update the mult...

Страница 124: ...the IP address of the multiviewer in the address bar The Kaleido Software home page appears 5 Click the XAdmin button The XAdmin Status and Options page appears 6 Click the Reset button at the end of...

Страница 125: ...ns audio monitoring output assignment for each RCP user sources channels and router configurations pointer size configuration If two multiviewers in a cascade are connected to the same router then the...

Страница 126: ...126 Configuring a Kaleido X16 Cascade Limitations...

Страница 127: ...ne Kaleido X16 multiviewer With a Kaleido IP Kaleido X16 Cascade system the Kaleido IP provides some parts of the monitor wall image sends it to the Kaleido X16 which adds some more elements to the ou...

Страница 128: ...output on the Kaleido IP to the second DVI input on the Kaleido X16 3 Connect the appropriate HDMI outputs on the Kaleido X16 to one or two monitor wall displays depending on the multiviewer model dua...

Страница 129: ...iviewer or change its IP address while the other member of the cascade is unavailable remove it from the cascade configuration first and then add it again after you made the required change You will t...

Страница 130: ...head order in your physical configuration To configure a cascade room 1 In XEdit while connected to the Kaleido X16 open the room you wish to configure Notes The system type is automatically adjusted...

Страница 131: ...a cascade room all logical sources from all the multiviewers associated with this cascade room are available When you save a Kaleido IP Kaleido X16 cascade layout any changes are automatically propag...

Страница 132: ...pair the cascade configuration 1 In XEdit connect to System B the multiviewer that was unavailable when the change was made once it is available again 2 In the Description Calibrations tab remove Syst...

Страница 133: ...g the other without waiting for the restart to be completed To upgrade a Kaleido IP Kaleido X16 cascade system 1 Load an empty layout on the monitor wall or make sure that the bottom area of the curre...

Страница 134: ...te to the RUN package you wish to install select it and then click Open The selected file is uploaded to the Kaleido IP This may take a few seconds Internet Explorer users If the page remains blank th...

Страница 135: ...ce you can monitor its progress if you wish or wait until the system prompts you to restart the Kaleido IP unit 8 Once the upgrade has completed if you wish to keep a copy of the log messages scroll d...

Страница 136: ...leido X16 upgrade package files to a USB key see Preparing a USB Key on page 107 14 Insert the USB key into any of the USB ports on the Kaleido X16 After a while a message appears at the bottom left c...

Страница 137: ...es are not automatically propagated to all members of a cascade If you wish to have the same configuration for every multiviewer in a cascade then the following elements must be manually replicated sy...

Страница 138: ...ted EDID auto detection is not supported When configuring a cascade room make sure the Use detected monitor resolution check box is not selected for any of its displays Refer to Enabling EDID Auto Det...

Страница 139: ...the video inputs are genlocked and two or three fields if the video inputs are not genlocked Signal inputs require BNC connectors Composite Inputs Signal NTSC SMPTE ST 170 NTSC J PAL BGDHI PAL N PAL M...

Страница 140: ...3Gbps Inputs Signal 4 2 2 SMPTE ST 424 2006 2 97 1 001 Gbps Formats 1080p50 1080p59 94 Audio SMPTE ST 299 1 Return loss 15 dB up to 1 485 GHz 10dB up to 2 97GHz Jitter 0 2 UI Cable length 100 m 328 f...

Страница 141: ...B4012DV Connector DVI I dual link HDMI Outputs Signal DVI D Resolution From 1024 768 to 1920 1200 NI all progressive scan H frequency 37 kHz to 96 kHz Refresh rate 50 59 94 Hz Cable length 5 m 15 ft 1...

Страница 142: ...en 1694A Alignment jitter 100 KHz 0 2 UI p p Connectors BNC 3G SDI Monitoring Outputs Signal 4 2 2 SMPTE ST 424 2006 2 97 Gbps 2 97 1 001 Gbps Formats Level A only 1080p50 1080p59 94 Audio SMPTE ST 29...

Страница 143: ...ype BNC HD SDI Router Outputs Signal 4 2 2 SMPTE ST 292 C 1 5 Gbps Formats 720p59 94 1080i50 1080i59 94 1080PsF23 98 1080PsF24 1080PsF25 1080PsF29 97 1080p23 98 1080p24 1080p29 97 Cable length 100 m 3...

Страница 144: ...AES3 digital audio and analog audio SDTI Audio Input Signal SMPTE ST 305 up to 128 channels 64 AES Cable length 250 m 820 ft Belden 1694A Connector BNC Analog Audio Output Signal Balanced analog audio...

Страница 145: ...dance 10k Connector BNC GPI INPUT up to 32 Description Contact closure to GND Pull up voltage 3 3 Volts Source current 30 A when input shorted Low level activation 0 8 Volts max Over voltage 24 Volts...

Страница 146: ...USB Signal USB Version 1 0 Connector USB Power supply Hot swappable redundant power supply Input voltage 100 240 V Frequency 47 63 Hz Power 300 W 75 of PSU Max current 4 A Max power 300 W Dimensions H...

Страница 147: ...rial 6 Yes Jupiter VM 3000 system controller Imagine Communications Harris Leitch Harris XY Passthrough Protocol No Platinum Xplus Integrator Via 32 Panacea Xpress Lantronix Lightwave Matrix Hub Proto...

Страница 148: ...homson Grass Valley Series 7000 devices our current implementation of the Series 7000 Native Protocol supports serial devices in addition to some Encore system controller models which are also support...

Страница 149: ...cated port number on the multiviewer in the case of a TCP IP protocol RS 422 Connection Diagram The Kaleido X16 supports two RS 422 serial inputs over RJ 45 connectors These inputs allow the Kaleido X...

Страница 150: ...rs chapter of the Kaleido Software User s Manual See Related Documentation on page 15 Note The two RS 422 ports on the Kaleido X16 side have no ground pin Using the appropriate DE 9S to RJ 45 adapter...

Страница 151: ...151 Kaleido X16 Hardware Description Installation Manual...

Страница 152: ...tain a local phone number for the support center nearest you consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the w...

Отзывы: