TopWinder
®
40
Belanger, Inc. ®* 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL755
Installation
Electric Motor Installation
Motor/Gearbox and LED Electrical Cables Routing
1) The Motor & LED Electrical Cables have been pre-routed through the driver side Arm
Assembly and the ends are extending out through the conduit fittings. Route both cables
through the Conduit supplied in the Accessory Box. Refer to the image below.
2) One end of the Motor/Gearbox Cable and LED Cable will be connected to their corresponding
Main Power Supply Line in the Electrical Enclosure, shown above.
3) On the other end the LED Cable has already been connected to the Slip Ring in the previous
section. The Motor/Gearbox cable will need to be connected to the Motor; remove the cover
on the Motor Electrical Box, route the Motor Cable through the Motor Cord Grip and secure to
the four (4) wire leads. See the image below.
CAUTION
It is recommended that a licensed electrician is contracted to perform all electrical installations.
4) After the Motor has been wired, secure the Upper Cover onto the plastic Motor Cover using
the supplied self-tapping screws.
Electrical
Enclosure
Motor/Gearbox
Cover Asy
Conduit Fitting
Conduit Fitting
Conduit
Conduit
Motor/Gearbox
and LED Cables
Driver Side
Arm Assembly
Screws (2)
Motor Main Power
LED Main
Power
Motor Electrical
Box Cover
Motor Cable
Motor Cord
Grip