background image

1

2019-11-15    #:146-9040-4    (2020-02-18)

ENG

DS-LEDFLAAF-3X3

Содержание DS-LEDFLAAF-3X3

Страница 1: ...1 2019 11 15 146 9040 4 2020 02 18 ENG DS LEDFLAAF 3X3 ...

Страница 2: ... exceed the Maximum Load Capacity Always use an assistant or mechanical lifting equipment to safely lift and position equipment This product is intended for indoor use only Use of this product outdoors could lead to product failure or personal injury Be careful not to pinch fingers when operating the mount For support please call customer care at 1 800 865 2112 WARNING Symbols ENG WARNING ENG Do n...

Страница 3: ...mbly 1 096 1721 I lower right wall plate assembly 1 096 1722 J vertical column double 2 096 1772 K vertical column single 2 096 1771 L M5 x 8mm 38 520 1144 M M5 x 6mm 4 520 9504 N wood screw 18 521 1688 O M4 x 75mm 36 521 1060 P 4mm allen wrench 1 560 9646 Q 3mm t handle allen wrench 1 560 0435 N 18 wood screw O 36 M4 x 75mm E 4 harness holder A 19 connector plate G 1 I 1 upper right wall plate as...

Страница 4: ...4 2019 11 15 146 9040 4 2020 02 18 J 2 vertical column double D 2 side trim C 3 vertical spacer B 2 horizontal spacer K 2 vertical column single ...

Страница 5: ... 11 15 146 9040 4 2020 02 18 34 11 866mm 33 80 858mm 58 44 1484mm 60 00 1524mm 103 67 2633mm 114 61 2911mm 21 5mm LED Trim not included 3 04 77mm 1 K Dimensions are for reference only Use spacers provided ENG ...

Страница 6: ...11 15 146 9040 4 2020 02 18 2 1 Use extrusion connectors to connect top horizontal wall plate assemblies ENG A 4 F G L 8 2 2 Use extrusion connectors to connect bottom wall plate assemblies ENG L 6 A 3 H I Q Q ...

Страница 7: ... a wood stud wall covered with plywood verify that the wood studs are a minimum of 2 x 4 nominal size and plywood is a minimum Grade BC 1 2 13 mm thick Plywood may be covered by gypsum board drywall up to 5 8 thick WARNING 3 3 1 Use a laser level to keep mounting holes level ENG ...

Страница 8: ...8 2019 11 15 146 9040 4 2020 02 18 3 2 Level wall plates and mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG F G ...

Страница 9: ...020 02 18 N 6 3 4 Level wall plates Install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG ENG 3 3 Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG 5 32 4mm 2 5 64mm 5 32 4mm ...

Страница 10: ...10 2019 11 15 146 9040 4 2020 02 18 Edges must be flush ENG 3 5 Secure vertical spacers to the wall flush with the horizontal extrusion ENG 3 8 10mm F N C 2 N 4 ...

Страница 11: ...0 4 2020 02 18 Edges must be flush ENG I H C C H 3 6 Use third vertical spacer to align bottom horizontal extrusion flush with vertical spacer then mark mounting holes on plywood must be minimum Grade BC 1 2 13mm thick ENG ...

Страница 12: ...20 02 18 3 8 Level wallplates Install using wood screws provided ENG 3 8 10mm Maximum 80 in lb 9 N M ENG ENG N 6 3 7 Drill mounting holes into supporting surface 1 75 44mm minimum depth required ENG 5 32 4mm 1 75 44mm 5 32 4mm C ...

Страница 13: ...13 2019 11 15 146 9040 4 2020 02 18 4 Remove vertical spacers C ENG 3 8 10mm C 3 ...

Страница 14: ...14 2019 11 15 146 9040 4 2020 02 18 5 1 Insert nuts for vertical assemblies using end of allen wrench ENG A A A A A 2 A 2 A 2 A 2 Q ...

Страница 15: ...15 2019 11 15 146 9040 4 2020 02 18 5 2 Attach vertical assemblies Do not tighten hardware ENG L 12 J K K Q ...

Страница 16: ...16 2019 11 15 146 9040 4 2020 02 18 5 3 Space vertical assemblies then tighten hardware ENG B 2 Q ...

Страница 17: ...17 2019 11 15 146 9040 4 2020 02 18 5 4 Insert vertical assemblies onto extrusions Do not tighten hardware ENG L 6 J Q ...

Страница 18: ...18 2019 11 15 146 9040 4 2020 02 18 5 5 Space vertical assemblies then tighten hardware ENG B 2 Q ...

Страница 19: ...19 2019 11 15 146 9040 4 2020 02 18 5 6 Insert vertical assemblies onto extrusions Do not tighten hardware ENG L 6 K K Q ...

Страница 20: ...20 2019 11 15 146 9040 4 2020 02 18 5 7 Space vertical assemblies then tighten hardware ENG B 2 Q ...

Страница 21: ...21 2019 11 15 146 9040 4 2020 02 18 6 1 Tie a string around the butterfly cut on outer columns in order to level the depth of each vertical column ENG Loosen adjust tighten ENG Q ...

Страница 22: ...22 2019 11 15 146 9040 4 2020 02 18 6 2 Tie a string around the butterfly cut on outer columns in order to level the depth of each vertical column ENG Loosen adjust tighten ENG Q ...

Страница 23: ...23 2019 11 15 146 9040 4 2020 02 18 6 3 With the string still attached level the height of each column Align string with slot in adaptor rail as shown ENG Tighten or loosen to adjust height ENG Q ...

Страница 24: ...24 2019 11 15 146 9040 4 2020 02 18 6 4 Check adaptor spacing after making adjustments ENG Q ...

Страница 25: ...25 2019 11 15 146 9040 4 2020 02 18 7 E 4 ...

Страница 26: ...26 2019 11 15 146 9040 4 2020 02 18 M 4 D 2 8 ...

Страница 27: ...27 2019 11 15 146 9040 4 2020 02 18 O 36 P 9 Assemble display cabinets display modules and trim per display manufacturer ENG ...

Страница 28: ...al Escobedo General Escobedo N L México 66062 Servicio al Cliente 01 800 849 65 77 www peerless av com 2020 Peerless Industries Inc Peerless AV 2300 White Oak Circle Aurora IL 60502 Email tech peerlessmounts com Ph 800 865 2112 Fax 800 359 6500 www peerless av com 2020 Peerless Industries Inc www peerless av com warranty Warranty Garantía Garantie Garantie Garantie Garanzia Záruka Záruka Garantia ...

Отзывы: