FLIPPING™ ARCH
1MANUL027
Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
23
Installation
Initial Start Up
1) Run water through the
Flipping
™
Arch and verify that there are no leaks in any of the
fittings or connections.
2) Actuate the 4-way valve on the air panel.
3) Verify that the Head Assembly Spray Manifold ROTATES correctly.
Verify that the Head Assembly Spray Manifold rotates 30° from center toward the
entrance of the wash and 30° from center toward the exit of the wash. See the
image below.
If the cylinder limiter is installed, verify that the spray manifold rotates 30° from
center toward the exit of the wash ONLY. See the image above.
Head Assembly
Spray Manifold
30°
30°
Toward Exit
Toward Entrance
Nozzle (4) for
Head Assembly
Spray Manifold
Head Assembly
Check Body (4) for
Head Assembly
Spray Manifold