Programming
Enterlink™ Setup
Setup
The Enterlink™ wash relay #1 will always correspond with package #1 of the Belanger Carwash
Controller. This can NOT be altered. The other three available Enterlink™ packages are what ever is
programmed on the Configurator Module at the first three “Option” packages. This simply means,
Enterlink™ package 2 is option 1 of the Configurator Module, Enterlink™ package 3 is option 2 of the
Configurator Module, and so on.
1. From the Enterlink™ Super Interface (hand held programming unit), use the “Command” key to
scroll through the available menus until you come to the “System Configuration” option. Select it
and enter the displayed password. Press <ENTER>. This is the Belanger default setup as
programmed by Unitec™.
2. Scroll to “Configuration Reset” and select option “1” (Reset All Memory).
3. You will be prompted to enter the manufacturer’s default configuration. Type the number “3” and
press <ENTER> (Belanger Default).
4. Select “Clear”. This will return you to the main programming screen.
5. Scroll until you see “Service Routines”. Select it.
6. Enter the following password: 62747.
Note:
All of the Unitec™ passwords are listed in the Unitec™ programming manual that comes
with the Enterlink™ system,
7. Scroll to “Print System Configuration” Select it. This is so you can visually review what the current
setup looks like.
Example:
The Enterlink™ is now prepared to work in harmony with the Belanger BAIS-T™ Configurator
Module.
Wash
Relays
1 2 3 4 5 6 7 8
Premium
x x x x x
Plus
x x x
Regular
x x
Express
x
To
package
1
To
option
1
To
option
2
To
option
3
To
option
4
To
option
5
To
option
6
To
option
7