BAIS-T™ CONFIGURATOR MODULE
54
Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL051
Reporting
Menu Options
13)
Print System Data
A report that outlines how all other system parameters
have been set up (such as: dollie call method, dollie
call delay, pulse length, wetdown time, etc.).
Keep in mind that the numeric values in the example
may represent different things depending on what the
particular data field parameters are.
Examples:
•
Shut Down Delay
- the number 10 represents seconds
•
Conveyor In Wet Down
- the 000001 means “YES” (000000 would
mean “NO”)
•
Output Modules Used
- the 3 means that there are three output
modules present for system output use
•
Dollie Up Method
- here the 3 selects “
Auto
” mode
•
Easy Length
- the 88 represents inches @ 7’ 4” dollie spacing
System Report
Wed Mar 05, 1997 09:41:49 AM
Shut Down Delay
:
000010
Conveyor In Wet Down :
000001
Wet Down Time
:
000030
Conveyor On delay
:
000030
Default Car Length
:
000060
Maximum Car Length :
000300
Minimum Car Length :
000060
Output Modules Used:
000003
Pulse Length
:
000785
Dollie Up Method
:
000002
Use Anti-Jam Logic :
000000
Dollie Call Method
:
000002
Dollie Call Delay
:
000000
Easy Length
:
000120
Front Dollies
:
000002
Rear Dollies
:
000001
Safety Length
:
000088
Set Conveyor Speed :
000400
Operation Mode
:
000001