background image

41

E

5. INSTALLATION

Your BEHRINGER ULTRA-CURVE PRO was carefully packed in the factory and the packaging was designed

to protect the unit from rough handling. Nevertheless, we recommend that you carefully examine the packaging

and its contents for any signs of physical damage, which may have occurred in transit.

+

If the unit is damaged, please do not return it to us, but notify your dealer and the shipping

company immediately, otherwise claims for damage or replacement may not be granted.

Shipping claims must be made by the consignee.

5.1 Rack mounting

The BEHRINGER ULTRA-CURVE PRO fits into two standard 19" rack units of space (3 1/2”). Please allow at

least an additional 4" depth for the connectors on the back panel. Be sure that there is enough air space

around the unit for cooling and please do not place the ULTRA-CURVE PRO on high temperature devices such

as power amplifiers etc. to avoid overheating.

5.2 Mains connection

The mains connection of the ULTRA-CURVE PRO is made by using a mains cable and a standard IEC

receptacle. It meets all of the international safety certification requirements.

+

Please make sure that all units have a proper ground connection. For your own safety, do not

remove the ground connection within the unit or at the supply, or fail to make this connection

at all.

Before you switch on the unit, check that it is configured to match your AC mains voltage requirements. If it

does not comply, then it is necessary to switch the operating voltage to the correct supply requirements

BEFORE turning on the unit, otherwise the unit could be severely damaged. You will find this combined fuse

holder/voltage selector at the back, adjacent to the IEC receptacle. 

IMPORTANT: This does not apply for

general export models which are built for one operating voltage only.

The AC voltage selection is defined by the position of the fuse holder. If you intend to change the operating

voltage, remove the fuse holder and twist it by 180 degrees before you reinsert it. Matching the two markers

monitors the selected voltage.

+

If the unit is switched to an other operating voltage, the ruse rating must be changed. See the

technical specifications in the appendix.

A safety fuse protects the unit from serious defects. If the fuse blows, this is a warning sign and always

indicates that the circuit is overloaded. The fault must always be repaired before the fuse is replaced. If the

safety fuse is faulty and needs replacing after the unit is repaired, please make sure that you replace it only

with the identical type and rating. NEVER use fuses of different ratings or cover faulty fuses with aluminium foil.

This can cause fire and electric shocks and will endanger your life and the lives of others.

5.3 Audio connections

As standard, the BEHRINGER ULTRA-CURVE PRO is installed with electronically servo-balanced inputs and

outputs. The new circuit design features automatic hum and noise reduction for balanced signals and thus

allows for trouble-free operation, even at high operating levels. Externally induced mains hum etc. will be

effectively suppressed. The automatic servo-function recognizes the presence of unbalanced connectors and

adjusts the nominal level internally to avoid level differences between the input and output signals (correction

6 dB).

+

Please ensure that only qualified persons install and operate the ULTRA-CURVE PRO. During

installation and operation the user must have sufficient electrical contact to earth. Electro-

static charges might affect the operation of the ULTRA-CURVE PRO!

5. INSTALLATION

All manuals and user guides at all-guides.com

all-guides.com

Содержание ULTRA-CURVE PRO DSP8024

Страница 1: ...1 E User s Manual Bedienungsanleitung D ULTRA CURVE PRO DSP8024 Version 1 0 October 1998 www behringer de All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...e designation and if applicable Article No which refers to this declaration is in accordance with the following standards or standardized documents x EN 60065 x EN 61000 3 2 x EN 55020 x EN 61000 3 3...

Страница 3: ...lation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliance including amplifiers that produce heat Power Source The applianc...

Страница 4: ...Ultra accurate Level Peak Meter with Peak Hold and selectable Reference Levels 4 dBu 10 dBV Dig Max s Full MIDI parameter and snapshot control for realtime editing s Free EQ Design software allows fo...

Страница 5: ...important member of the BEHRINGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you...

Страница 6: ...E PRO in the recording studio 28 3 4 The ULTRA CURVE PRO as part of a keyboard setup 28 3 5 The ULTRA CURVE PRO in a guitar setup 29 3 6 The ULTRA CURVE PRO as anADC AES EBU Option 29 3 7 The ULTRA CU...

Страница 7: ...6 2 Changing the memory protect battery 44 6 3 MIDI implementation 45 6 4 Software 46 6 4 1 Operating software 46 6 4 2 PC software EQ Design 46 6 5 Technical Specifications 50 7 WARRANTY 53 All manua...

Страница 8: ...ploys the best choice of components Top quality 24 bit AD DA converters which belong to the best components avail able owing to its outstanding specifications and excellent sonic characteristics Two 2...

Страница 9: ...ssages Control of the ULTRA CURVE PRO is carried out by using three KEY GROUPS each consisting of four keys On the left of the front panel the keys for operation and bypass are to be found above each...

Страница 10: ...selected voltage Please note that depending on the mains voltage supplied to the unit the correct fuse type and rate must be installed see chapter 6 4 Technical Speci fications Please use the enclosed...

Страница 11: ...TRA CURVE PRO is switched from one mode to the other the outputs will be briefly muted 2 1 EQ mode 2 1 1 Operating the Graphic Equalizer Upon switching on the ULTRA CURVE PRO you will be presented eit...

Страница 12: ...the LEVEL METER and return to the main EQ window With key B you erase the maximum levels from the memory With key C you switch the display from the ULTRA CURVE PRO input and output With key D you can...

Страница 13: ...how whether the parameters are fixed or are set for automatic search to function as the FEEDBACK DESTROYER The following modes are possible Code Mode AUT Automatic Search SGL Single Shot Search LCK Lo...

Страница 14: ...switched on or off The display shows the current status switched off switched on signal will be delayed by the preset numerical value You can set the DELAY time in the EQ SETUP menu see chapter 2 1 6...

Страница 15: ...n is selected with the vertical cursor keys is confirmed with or cancelled with If a program location is already occupied the warning OVERWRITE PROGRAM will appear Pressing once more allows you to con...

Страница 16: ...maintained while the overall slope is altered You can create curves with varying slopes the slope can be adjusted in 3 dB steps from a slope of 6 to 30 dB per octave Having confirmed the edit with th...

Страница 17: ...independent of each other CROSSFADE The CROSSFADE function causes a soft or gradual transition from one program when switching into another This helps prevent any clicks or other noises which can be c...

Страница 18: ...s the precise values pertaining to the selected frequency along with the number of the RTA program currently in use By moving the crosshairs to any given frequency band or the overall level you can di...

Страница 19: ...le between maximum hold on off To indicate that the hold function is on will become bold The softkey C will reset the maximum value indicators With key D or you can switch between manual and automatic...

Страница 20: ...AUTO Q function If no program number has been given FLAT will be displayed meaning that an attempt will be made to achieve a linear response GAIN MODE The ULTRA CURVE PRO analyzer is capable of settin...

Страница 21: ...uted into the outputs when you switch into RTA mode As a rule Pink Noise is used for system measurement Use the RTA lock function to prevent accidental signal interruption when using the ULTRA CURVE P...

Страница 22: ...noise test signal This means that the individual EQ bands are adjusted When the AUTO Q process is finished the ULTRA CURVE PRO can be set in EQ mode where it automatically displays the achieved EQ se...

Страница 23: ...tuation where you are using the ULTRA CURVE PRO as a P A equalizer and somebody by accident presses the RTA key This could even in the worst case result in the concert sound which you had so carefully...

Страница 24: ...neral setup pressing the SETUP key will toggle between GLOBAL SETUP and MIDI SETUP MIDI Here the MIDI function is switched on or off Toggle between ON and OFF with the buttons CHANNEL This field indic...

Страница 25: ...erved by a crossover you must pay particular attention to travel path time differ ences and phase coherence between the different components of the system The BEHRINGER SUPER X crossover with its vari...

Страница 26: ...nts These measurements can be used as a control of the basic system functions Position 3 is about seven feet in front of the stage centre Measurements taken here should show an identical response abov...

Страница 27: ...und characteristics have similarities to sine waves cannot be distinguished from feedback resulting in their signal being constantly dampened If in SEARCH mode all the available filters are being used...

Страница 28: ...using the STEREOLINK function you need only set one channel of the equalizer to achieve the desired EQ setting The parametric filters are also very useful for this purpose By using the optional AES EB...

Страница 29: ...ntrolled amplifier You can integrate the ULTRA CURVE PRO into this setup as an equalizer and gain adjusting device you can save the masterfader positions for each of your presets 3 6 The ULTRA CURVE P...

Страница 30: ...aving a dedicated delay unit The delay settings are be stored with the program If several groups of identical loudspeakers are being used each having a different Delay time they can be controlled by a...

Страница 31: ...alog techniques the dynamic range of digital equipment is approxi mately 25 dB less With conventional record and tape recorder technology as well as broadcasting this value is further reduced Generall...

Страница 32: ...the audio signal if sudden level peaks occur Technically speaking we refer to this reserve as headroom usually this is about 10 20 dB A reduction of the operating level would allow for greater headro...

Страница 33: ...e signal exceeds the threshold The output of a compressor will still rise if the input level is increased while the maximum output of a limiter will always be equal to the threshold level Generally th...

Страница 34: ...amplitude and giving it a numerical value This form of measuring the signal regularly over a period of time is known as sampling the conversion of the amplitude into a numerical value quantizing The t...

Страница 35: ...versation Rate 8 7 6 5 4 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Quantization Errors Noise Continuous Analog Signal Fig 4 3 Transfer diagram for an ideal linear ADC 2 s complement representation Digital dis...

Страница 36: ...format AES EBU ID data Table 4 3 shows the corresponding data of the consumer format commonly used for S PDIF connections The first bit serves to identify the following data as professional or consum...

Страница 37: ...n it having characteristics which need to be explained here Equalizer settings with extreme differences in levels between adjacent frequency bands require in some cases internal boosting and attenuati...

Страница 38: ...mplifier and are then fed to the A D converters Here they are converted into a time division multiplex digital signal suitable for the DSPs The reference microphone input feeds a balanced amplifier wh...

Страница 39: ...balanced outputs In the case of an ULTRA CURVE PRO with fitted AES EBU option the digital signal on leaving the DSPs will be sent to the digital output as well as to the D A converter The digital out...

Страница 40: ...the BEHRINGER ULTRA CURVE PRO allows audio spectral analysis with a 1 3 octave resolution to an accuracy of 0 5 dB The associated display may be customized in a number of different ways to suit your p...

Страница 41: ...does not apply for general export models which are built for one operating voltage only The AC voltage selection is defined by the position of the fuse holder If you intend to change the operating vol...

Страница 42: ...nput Output Tip Signal Tip hot ve Sleeve Ground Shield Sleeve Ground Shield Tip Tip Sleeve Sleeve Strain relief clamp Strain relief clamp Ring cold ve For connection of balanced and unbalanced plugs r...

Страница 43: ...was developed in the early 1980s to allow electronic musical instruments from different manufacturers to communicate with each other The use of MIDI has developed over the intervening years to the sta...

Страница 44: ...ssible We are able to replace the battery without losing the programs stored in the memory If you fail to heed the warning to replace the battery the display will show the message BATTERY EMPTY MEMORY...

Страница 45: ...X X Real Time Commands X X Aux Local ON OFF X X All notes OFF X X Messages Active Sense X X Reset X X Notes X X O YES X NO Mode 2 OMNI ON MONO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO 1 100 0 99 0 9...

Страница 46: ...to control one or more ULTRA CURVE PROs via MIDI with extra functions and improved ease of use The software requires an IBM compatible PC with a MIDI interface All ULTRA CURVE PRO features are control...

Страница 47: ...ht or by pressing the corresponding pictograms the resulting frequency response curve of the non dynamic operations of the ULTRA CURVE PRO is shown with the corresponding phase response Each time CURV...

Страница 48: ...windows Using a computer to display the Real Time Analyzer has the advantage of a larger display and color represen tation Various functions of the RTA can be controlled here Due to the constant devel...

Страница 49: ...49 E Fig 6 7 RTA window 6 APPENDIX All manuals and user guides at all guides com...

Страница 50: ...z THD N 0 004 1 kHz 4 dBu Crosstalk 103dB 22 Hz to 22 kHz Bypass Type Relay controlled Bypass Reference Microphone Input Type Servo Balanced Input Impedance 2 kOhms Nominal Operating Level 60 dBu to 0...

Страница 51: ...gital Delay Type Digital Stereo Delay Maximum Delay Time 2 5 sec independently adjustable for each channel Minimum resolution 0 1 msec Delay unit Seconds metres or feet Level Meter Type Digital Level...

Страница 52: ...0 V AC 50 Hz Generelles Export Modell 100 120 V AC 200 240 V AC 50 60 Hz Power consumption 21 W Fuse rating 100 120 V AC 630 mA Typ T Slow blow 200 240 V AC 315 mA Typ T Slow blow Mains Connection Sta...

Страница 53: ...DAMAGES Failure of BEHRINGER INTERNATIONAL to provide proper war ranty service shall not entitle the buyer to claim consequential damages In no event shall the liability of BEHRINGER INTERNA TIONAL ex...

Страница 54: ...All manuals and user guides at all guides com...

Страница 55: ...All manuals and user guides at all guides com...

Страница 56: ...All manuals and user guides at all guides com a l l g u i d e s c o m...

Отзывы: