PF1352 USER MANUAL REV A 12/21/15
SECTION ONE
1.2
SPECIFICATIONS FOR AC POWER SUPPLY PF 1352 SERIES
INPUT POWER REQUIREMENTS:
95* to 270 VAC, 47 - 63 Hz @ 16A Max.
(Full
power
from
108V
–
267V)
(*)
input
current
limited
to
16A.
AC OUTPUT POWER:
1200W (with 120 – 270 VAC Input)
OUTPUT
FREQUENCY:
Variable
from 45 – 500Hz (45 -1000 E opt.)
AC
OUTPUT
T.H.D.
1.5%
TYPICAL @ 120V / 50Hz, resistive load.
AC OUTPUT CURRENT:
10A @ 135V RANGE, 5A @ 270V RANGE.
AC OUTPUT REGULATION:
0.7 % No load to Full load, (resistive).
LINE REGULATION:
0.7% for 10% line change.
METERING:
VOLTAGE:
+/-
(0.5%
of
r/- 2 LSD), 0.1V res.
CURRENT:
+/-
(1%
of
r /- 5 LSD), 0.1A res.
FREQUENCY:
+/- 1Hz 0.1Hz res.
POWER:
+/- 2.5%, of F.S. (150–1200W) 1W res.
POWER
FACTOR:
+/-
2.5%
of F.S. (150-1200W) 0 - .99
PHYSICAL:
19”(482mm) W x 17”(431mm) D x 3.5”(88mm) H
EIA standard rack mount cabinets (with RM kit).
WEIGHT:
39
lbs.
(17.6
kgs)
OPERATING TEMPERATURE:
0 to +40 degrees Celsius.
STORAGE TEMPERATURE:
-10 to +60 Degrees Celsius.
SAFETY:
Evaluated to IEC-61010, general safety, protection
Class1,
pollution
level
2.
OPTIONAL
Remote
interface
safety
and
Isolation
conform
to
IEC-
60950-1.