CONTROLS AND INDICATORS
Table 3-1 below lists the controls, indicators, and other features associated with the
model PF1352 AC power supply. Refer to figure 3-1 for locations.
TABLE 3-1
ITEM DESIGNATION
COMMENT/DESCRIPTION
1
AC line
POWER
switch
Power on/off switch.
2
Alpha Numeric Display
Displays output parameters and settings
3
OUTPUT
Switch
Push button switch controls application of AC
voltage to output terminals. Push to turn on.
4
RANGE
Switch
Push button switch controls range of AC
output voltage. Selects between 0-135V (low)
or 0 -270V (high). Push in for
HIGH
range.
5
LOCAL REMOTE switch
On older models, this switch selected between
local and remote operation. A version units do
not use this switch .
6
SHIFT
“key”
Used in conjunction with control “keys” to set
output parameters. Set s the adjustment
resolution to x0.1, x1,x10, or x100
7
Control “Keys”
Used in conjunction with
SHIFT
key to set
display and output parameters.
MODE
selects
the parameter to be adjusted.
UP/DOWN
provides adjustment with the currently
selected resolution.
8
LED indicators
Indicate status of : Output, Range, and com.
function (
BUSY
)
9
Output Terminal Block
Enclosed type 3 position wire terminals.
10
AC input receptacle
IEC- 19 type AC receptacle.
11
Input Line fuse (F1)
6.3 x 32mm, 16A, 300Vac fuse. CAUTION,
replace with same type and rating only.
12
REMOTE INTERFACE
Provides remote control via RS-232, USB, or
Ethernet type hardware interface and boot
switch.
13
RESET
Recessed push button , reset controller and
interface to power on condition.