PF1352 USER MANUAL REV A 12/21/15
6.4 Webpage
The power supply hosts a webpage that can be accessed through any W3C web
compliant browser using the IP address or hostname of the power supply. By factory
default, the Hostname is “BEHLMAN” and the IP address is set up through the DHCP
server. Figure 6-14 shows the webpage’s Overview tab.
Figure 6-14 Overview Tab
Note: If two power supplies have the SAME hostname, the power supply with the lowest
IP address value will respond to the browsers request to view the webpage. For
example, if two power supplies have IP addresses 90.0.0.32 and 90.0.0.34, the power
supply with IP address 90.0.0.32 will respond to the webpage request. The hostname
can be changed using the
SYSTem:COMMunicate:LAN:HOSTname
command. More
information about the hostname can be found in section 6.2.5.
The System Control tab, Trigger Control tab, and Network Configuration tab are
password protected. In order to view those tabs, the user must enter the username and
password.
Factory default:
Username: “admin”
Password: “DEFAULT”
The username and password are both case sensitive. The password can be changed
using the
SYSTem:PASSword:NEW
command. The password can be reset to factory
default by turning the power supply on in boot loader mode. More information about the
password can be found in section 6.2.6. More information about the boot loader
operation and the reset conditions can be found in section 6.2.7.