PF1352 USER MANUAL REV A 12/21/15
3.12 OPERATION
WITH
REMOTE CONTROL
The PF1352 is available with several remote control options. These are:
1. RS-232 ,USB, or Ethernet computer control (standard)
2. IEEE-488 computer control (I option)
3. 0-10VDC Analog Remote Control (A option)
Each of the options allows control of the following:
1. Output Voltage Setting
2. Output Frequency Setting
3. Output on/off function
4. Output Range function
5. Current limit Setting* (* not available with analog remote).
In addition, the standard versions allow remote monitoring of output voltage, frequency
current, power, and power factor. System status may also be “polled” to check for
operational problems such as overloads or over temperature.
The specific information for each option will be included at the end of this document as
an appendix. Note that only one option may be included. Check the rating label to see if
options have been installed.
ISOLATION AND SAFETY
The provided remote control interface meets the general safety and isolation
requirements of IEC 60950 for class1 equipment. This interface is intended to be
connected to properly grounded “ITE” equipment. Contact Behlman for additional
information.