Beech Ovens
Page 83
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
Installation Check Sheet
Assembly Check:
□
Flue System.
□
Fitted Oven Components.
□
Access above and below oven.
Ensure that ONLY non-combustible materials are used in the construction of any façade
surrounding the oven, including the areas closest to the oven steelwork, e.g. doors and windows.
Exhaust Type:
Check that the Exhaust Duct installation is compliant with local regulation.
Spray Filter.
□
Flue Transition.
□
Canopy.
□
Other: ____________________
(Spray Filter)
Water connected.
(Spray Filter)
40mm Drain connected.
(Spray Filter)
Power connected and linked to Exhaust fan circuit.
Gas Connection:
All Gas fittings tight and correctly connected.
Gas control cabinet and Burner(s) mounted firmly in position.
Shrouds firmly in place.
Gas Type corresponds to that stated on the Data plate located in the Gas control cabinet.
Burner connected to Gas control cabinet.
For Dual burners
– Tube burner connected to “Burner 1” connection on Gas control cabinet.
Electrical Connection:
Check that all wiring and cabling is routed correctly.
All electrical components correctly installed
– Mains Electricity Supply sufficient earthed and in accordance
with local regulation.
Correct Polarity
(Power (Live) = Brown Neutral = Blue Earth = Green)
Tri-Electrode connections and corresponding cabling is correctly fitted.
(All burners: Zones 1 & 2)
Spark evident.
General Installation Check:
Legs fastened sufficiently to floor (if applicable)
– oven is stable in position.
Outer ceramic wool insulation complete and well fastened.
25mm Air Circulation Gap evident.
If applicable, check that the Stainless Steel Hearth is fitted correctly, level with the floor bricks.
Check that the area below and surrounding the oven is clean, tidy and free of debris.
Check to ensure that suitable fire extinguishing equipment is close at hand.