Beech Ovens
Page 120
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
CE Specifications
The following table outlines the technical details for ovens installed within the CE
region.
Natural Gas
Country
Category
Nominal
Pressure
Heat Input
Nominal
Rate
Injector
Diameter
DE
12ELL
20mBar
G20: 22kW
G25: 19kW
2.3m ³/Hr
3.5mm (28 gauge)
AT, DK, ES,
FI, IE, IT, PT,
GB, SE, CH
12H
20mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
BE, FR
12Er
20mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
Propane
DE, NL, CH,
FR, ES
13P
50mBar
G31: 18.5kW
1.44kg /Hr
2.2mm (44 gauge)
PT, GB, CH,
FR, ES
13P
37mBar
G31: 18.5kW
1.44kg /Hr
2.2mm (44 gauge)
Note:
CH, FR and ES allow both 37 and 50mBar
Timber Consumption:
Hardwood
0.1m
³
/ day
Airflow required:
700 litres / sec. Suction controlled by system damper. (Direct connect)
Duct Size: Natural Draft
300mm square (900cm²) or equivalent area round.
Duct Size: Fan assisted
300mm square (900cm²) or equivalent area round.
Duct Material:
1.2mm galvanised or 0.9mm stainless steel
(As per local regulation)
Secondary Air for gas
burner:
6 litres / sec (approximately)
Air conditioning Heat
Load:
<2 kW heat load
Electrical Data:
220-240 Volts 50 Hz ac 10 Amp supply with earth