Beech Ovens
Page 54
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
Tri-electrode connection point
(RND1300 Round oven with
Tube burner shown)
The cables for the Tri-electrode
are found in the Gas control
cabinet.
Connect the high-tension leads from the Flame Pack to the Tri-electrode at the burner
head. The cables will normally be delivered coiled within the Gas control cabinet. These
connectors are colour-coded and different sized plugs to ensure connection cannot be
mixed up.
NOTE:
When coiling the leads to the Tri-electrode, be sure not to kink or damage the
leads. The leads are to be routed in a tidy manner using the supplied clips and
cable ties under the oven base ensuring that they are not attached to other
cables, metallic or sharp objects.
NOTE:
Connection points vary with different burner and Oven types. Where a display
and
a Tube burner are fitted, the Display burner will ALWAYS assume position 2
(Default burner). This is done to ensure that the Tube burner will cycle between High
Flame and Low Flame and the Display burner will always remain on as a feature burner.