
Beech Ovens
Page 31
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
Oven Facade
Exhaust Exit temperature less
than 100°C
(@700l/sec
– 1000l/sec for 2
door oven)
Cool Air make-up unit.
Approx 30°C
(@ approx 550 l/sec)
Fresh air
(approx 22°C)
mixes with hot air from
oven cavity
Exhaust Temperature
entering Spray filter
approx 150-180°C
(@ approx 150l/sec)
Optional manually activated
Ansul Spray head for fire
protection
(Refer to local specialist)
Optional high temp
sprinkler head connected to
sprinkler system
Oven Temperature
approx 350°C
Cyclonic Filter helps
to removes pollutants
(Creosote, ash, etc)
Spray Filter normal operating Temperatures and Air flow volumes
The diagram below identifies the normal operating temperatures for the Spray filter
System.
NOTE:
Normal operating temperatures should be under 100°C. This will
rapidly increase due to the following; Fan failure, Power Failure and/or
Mechanical Ventilation Failure.
If an Ansul system is required, we recommend a single head at top of the exhaust
spigot which should be manually activated by the oven operator.