Beech Ovens
Page 64
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
Electrical Connection
The system will require the following earthed mains electricity supply;
220-240 Volt
(other voltages available by request)
50Hz
10 Amp
Within the Gas cabinet a power supply cable is supplied connected to an Australian
standard plug. Should your oven be installed outside of Australia, a common practice is
to purchase an adapter to suit your local socket configuration.
In some instances a new plug may be fitted to suit your local socket configuration, or
you may wish to hard-wire your system to an isolator. If these methods are used,
ensure to adhere to the following instruction.
NOTE:
Power supply to the system is
polarity sensitive
. The following colour
codes
MUST
be adhered to for your system to operate.
Brown = Active / Live
Blue = Neutral / Common
Green = Earth
Final Checks
1. Check all gas, mechanical and electrical connections to all equipment. Ensure
that the burner and shroud are firmly located.
2. Check gas flow logic, opening all relevant manual valves.
3. Proceed with start up procedure outlined in the Commissioning section of this
manual.