IMPORTANT INSTRUCTIONS
BEDJET USER OPERATING MANUAL
Revision 1.0
www.bedjet.com
P a g e | 21
Diagnose & Fix
Issue
Possible Causes
Action
Remote control will not
operate BedJet
Dead battery in remote
Remote control has a unique code
identifier and may need to be re-
paired to your BedJet
Make sure remote control LED lights
when button pressed, if not then
replace battery
Re-pair remote control to BedJet
with learning function on page 9
Remote control commands are
not acknowledged with a beep
anymore
Beeper mute may have been
accidentally turned on
Press Mute button on remote
control to unmute beeper
BedJet keeps shutting off
without a shutoff command
being given or beep; BedJet
POWER LED is ON and NOT
flashing and BedJet can be
restarted normally.
This is normal. Once turned on,
every mode has an automatic
shutoff timer. Please see page 12
for these auto-shutoff time limits.
Shutoff Timer can be advanced
within certain limits using timer
advance button
BedJet Power LED is flashing
and unit will no longer operate,
BedJet beeps 5 times
The BedJet microprocessor has
discovered a monitoring error
within the system. This does not
always mean your BedJet is
malfunctioning and typically may
occur you rapidly change modes or
airflow while at the same time
obstructing inlets or outlets.
Check to make sure air filter is clean
and there are no air inlet or outlet
obstructions
Shut the BedJet off for 10 seconds
and restart. If this does not solve
the problem, or if the problem
occurs again, contact BedJet support
and record the number of flashes
from the Power LED.
BedJet Power LED is on, but
when BedJet is commanded
into any Air Flow mode the unit
shuts off, the display goes dark
and then turns back on again,
and system will not blow air.
In addition to real time
microprocessor control of the
heat, the BedJet contains multiple
mechanical thermal overheat
switches for your protection. They
are extremely sensitive and may
have disabled the unit. They are
self-resetting but remain open
until power is removed and the
unit is allowed to cool off.
Switch off BedJet and unplug for 15
minutes. Plug back in and turn on
and attempt to operate the system.
Check air filter to make sure it is
clean
If this does not solve the issue,
contact BedJet support.
If the above solves the issue but the
problem repeats again later then
contact BedJet support