Mounting and connection
EP4174-0002
19
Version: 1.1.0
Ethernet/EtherCAT
Plug connector
Cable
Standard
Signal
Description
M8
M12
RJ45
1
ZB9010, ZB9020,
ZB9030, ZB9032,
ZK1090-6292,
ZK1090-3xxx-xxxx
ZB9031 and old ver-
sions
of ZB9030, ZB9032,
ZK1090-3xxx-xxxx
TIA-568B
Tx +
Transmit Data+
Pin 1
Pin 1
Pin 1
yellow
2
orange/white
3
white/orange
Tx -
Transmit Data-
Pin 4
Pin 3
Pin 2
orange
2
orange
3
orange
Rx +
Receive Data+
Pin 2
Pin 2
Pin 3
white
2
blue/white
3
white/green
Rx -
Receive Data-
Pin 3
Pin 4
Pin 6
blue
2
blue
3
green
Shield
Shield
Housing
Shroud
Screen
Screen
Screen
1
) colored markings according to EN 61918 in the four-pin RJ45 connector ZS1090-0003
2
) wire colors according to EN 61918
3
) wire colors
Assimilation of color coding for cable ZB9030, ZB9032 and ZK1090-3xxxx-xxxx (with
M8 connectors)
For unification the prevalent cables ZB9030, ZB9032 and ZK1090-3xxx-xxxx this means the pre as-
sembled cables with M8 connectors were changed to the colors of EN61918 (yellow, orange, white,
blue).So different color coding exists. But the electrical properties are absolutely identical.
EtherCAT connector
The following connectors can be supplied for use in Beckhoff EtherCAT systems.
Name
Connector
Comment
ZS1090-0003
RJ45
four-pole, IP20, field-configurable
ZS1090-0004
M12, male
four-pin, IP67, for field assembly
ZS1090-0005
RJ45
eight-pole, IP20, field-configurable, suitable for gigabit Ethernet
ZS1090-0006
M8 plug connector
four-pole, IP67, field-configurable, for cable type ZB903x
ZS1090-0007
M8 socket
four-pole, IP67, field-configurable, for cable type ZB903x
ZS1090-1006
M8 plug connector
four-pole, IP67, field-configurable up to OD = 6.5 mm
ZS1090-1007
M8 socket
four-pole, IP67, field-configurable up to OD = 6.5 mm