4.12
Fieldbus connection
4.12.1
CANopen interface (X7)
The interface for connection to the CAN bus (default: 500 kbps). The master is fitted with
a CAN input. All axis modules in the system are connected to this through the internal
bus. The last axis module has a CAN output, where the CAN bus either continues to
other bus participants or is terminated by a termination resistor.
The integrated profile is based on the communication profile CANopen DS301 and the
drive profile DS402. The following functions are available in connection with the integra-
ted position controller: Jogging with variable speed, homing, start motion task, start direct
task, digital setpoint provision, data transmission functions and many others.
Detailed information can be found in the CANopen manual.
The interface is at the same potential as the internal logic, and uses AGND as the ground
reference.
AGND must be connected to the control system ground for potential equalization!
CAN bus cable
To meet ISO 11898 you should use a bus cable with a 120
W
characteristic impedance.
The maximum usable cable length for reliable communication decreases with increasing
transmission speed. As a guide, you can use the following values which we have measu-
red, but they must not be assumed to be limits:
Cable data
: Characteristic impedance
100-120
W
Cable capacitance
max. 60 nF/km
Conductor loop resistance
159.8
W
/km
Cable length, depending on the transmission rate
Transmission rate / kbps
max. cable length / m
1000
20
500
70
250
115
Lower cable capacitance (max. 30 nF/km) and lower lead resistance (loop: 115
W
/km)
make it possible to transmit over longer distances.
(Characteristic impedance 150 ± 5
W Þ
terminating resistance 150 ± 5
W
).
For EMC reasons, the SubD connector housing must fulfill the following conditions:
—
metal or metallized housing
—
provision for connecting the cable shielding within the housing,
large-area connections
AX2500 Installation Manual
57
Beckhoff
02/06
Interfaces
AX2500
Содержание AX2500 Series
Страница 22: ...This page has been deliberately left blank 22 AX2500 Installation Manual Technical description 02 06 Beckhoff...
Страница 26: ...3 3 1 Dimensions 26 AX2500 Installation Manual Installation 02 06 Beckhoff AX250x and AX251x AX252x...
Страница 31: ...3 4 4 Connector assignments AX2500 Installation Manual 31 Beckhoff 02 06 Installation...
Страница 36: ...This page has been deliberately left blank 36 AX2500 Installation Manual Installation 02 06 Beckhoff...
Страница 60: ...This page has been deliberately left blank 60 AX2500 Installation Manual Interfaces 02 06 Beckhoff...
Страница 65: ...5 3 2 3 Status display on the master AX2500 Installation Manual 65 Beckhoff 02 06 Setup...
Страница 68: ...This page has been deliberately left blank 68 AX2500 Installation Manual Setup 02 06 Beckhoff...
Страница 81: ...This page has been deliberately left blank AX2500 Installation Manual 81 Beckhoff 02 06 Appendix...