Upper stop to lower point
Open to the permanent upper stop.
▻
The tubular drive switches off automatically.
Put the tubular drive into programming mode.
>5s
Press a travel button for >5 seconds on a transmitter that has already been pro-
grammed in order to switch to installation mode.
▻
The tubular drive confirms.
A drive command is executed when a button is pressed for more than
1 second.
Then close to the desired lower limit position.
2x
<1s
Press the down button twice within one second to set the point.
▻
The tubular drive confirms.
►
The limit positions are now set.
4x
4x
<1s
Press a travel button 4 times within one second to exit the installation mode.
►
The tubular drive confirms.
Upper point to lower stop
Put the tubular drive into programming mode.
>5s
Press a travel button for >5 seconds on a transmitter that has already been pro-
grammed in order to switch to installation mode.
▻
The tubular drive confirms.
A drive command is executed when a button is pressed for more than
1 second.
Open to the desired upper limit position.
2x
<1s
Press the UP button twice within one second to set the point.
▻
The tubular drive confirms.
Then close to the permanent lower stop.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.
4x
4x
<1s
Press a travel button 4 times within one second to exit the installation mode.
►
The tubular drive confirms.