background image

Declaration of conformity

24 - en

Содержание enocean P5-16

Страница 1: ...th integrated radio transceiver Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 301 121 0 28 05 2020 ...

Страница 2: ...on 9 Mounting the drive in the tube 10 Antenna installation 11 First operation 12 Programming transmitter 13 Clear transmitter 13 Checking that the running direction is correct 13 Intelligent installation management 13 Indicador de estado de las posiciones finales IEPF 13 Setting the limit positions 13 Upper stop to lower stop 14 Upper point to lower point 14 Upper stop to lower point 15 Upper poi...

Страница 3: ...it Suitable for rigid aluminium steel and wooden profiles The limit positions do not have to be reset Changes in the shading solution are accommodated automatically when using stop systems Torque control in the up direction prevents damage to the roller shutter in the event of a frozen or blocked shutter Anti freeze mechanism in the upper limit position can be enabled Considerably reduced stop loa...

Страница 4: ...olved Children must not play with the device Systems have to be checked regularly by authorised specialists for wear and damage Always put damaged systems out of operation immediately until they are repaired by an authorised specialist Do not operate equipment if people or objects are within the danger zone Observe the danger zone of the equipment during operation Ensure that there is adequate cle...

Страница 5: ...structions If the drive is used for shading solutions in a specially marked area e g escape routes hazard zones safety areas compliance with all applicable regulations and standards must be ensured Caution Safety instructions for avoiding serious injuries When electrical or electronic equipment and units are operated certain components e g the power supply unit are live Physical injuries or damage...

Страница 6: ...tube Other applications uses and modifications are not permitted in order to protect the safety of the users and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or re...

Страница 7: ...e flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locat ing lug from the plug Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver A 1 2 A A snap in pin A locating latch 7 en ...

Страница 8: ...s in the guide tracks Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is al...

Страница 9: ...he drive adapter with safety catch on the drive shaft Disassembly with disassembly tool Item no 4930 300 606 0 Disassembly with long nose pliers 2 1 Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection 9 en ...

Страница 10: ...e barrel Attention Do not hammer the tubular drive into the tube or drop it into the barrel The curtain can only be secured using springs or rigid shaft connectors We recommend at least three pieces per metre of barrel Assemble the tubular drive with the relevant ring 1 and drive adapter 2 If the ring has several grooves select the groove which is a perfect fit and push the ring 1 onto the thrust ...

Страница 11: ...Antenna installation Lay and fix the antenna end in the lower part of the box near the guide rail Attention Make sure that the antenna cannot be detected by the roller shutter curtain 11 en ...

Страница 12: ...tubular drive for programming with the radio switch Switch the radio switch to the inside position If the radio switch is already in this posi tion switch it to the outside and back to the inside position The tubular drive confirms The tubular drive is ready to program for 3 minutes If several tubular drives are to be connected in parallel you can deactivate the program ming mode on one tubular dr...

Страница 13: ...tion following automatic setting of limit positions The drive saves the limit position permanently once the upper limit position is reached 3 times in succession Installation is then complete If the limit position is set above a point this is stored permanently Indicador de estado de las posiciones finales IEPF A brief stopping and restarting indicates that no limit position has been set in that d...

Страница 14: ...top The tubular drive switches off automatically The limit positions are now set Upper point to lower point There is no shading solution length adjustment with this limit position setting Put the tubular drive into programming mode 5s Press a travel button for 5 seconds on a transmitter that has already been pro grammed in order to switch to installation mode The tubular drive confirms A drive com...

Страница 15: ...a travel button 4 times within one second to exit the installation mode The tubular drive confirms Upper point to lower stop Put the tubular drive into programming mode 5s Press a travel button for 5 seconds on a transmitter that has already been pro grammed in order to switch to installation mode The tubular drive confirms A drive command is executed when a button is pressed for more than 1 secon...

Страница 16: ...e shading solution to the limit position that is to be deleted Carry out the following sequence without interruption between the individual drive commands until STOP 4x 4x 1s Press a travel button 4 times within one second to exit the installation mode The tubular drive confirms Deleting both limit positions Put the tubular drive into programming mode 5s Press a travel button for 5 seconds on a tr...

Страница 17: ... within one second The curtain runs to the intermediate position assigned to the travel button Deleting the desired intermediate position 5s Press the travel button assigned to the intermediate position for 5 seconds The shading solution moves to the intermediate position and the tubular drive confirms The intermediate position is now deleted Programming additional transmitters Up to 14 transmitte...

Страница 18: ... handle with EnOcean wireless technology is turned to the tilted position the shading solution moves to intermediate position II If the window handle is turned back to the closed position the shading solution moves to the original position If the shading solution has been moved in the meantime and the window handle is turned to the closed position the shading solution will not move to the original...

Страница 19: ...ossible to travel in both directions again The following are detected Moving DOWN A curtain jam when closing due to objects on the window sill or sticking of the lateral guide tracks To ensure complete closing of the roller shutter curtain at the lower limit position the curtain does not reverse once it gets to ap prox 360 from the lower limit position To ensure that the roller shutter curtain saf...

Страница 20: ...enable Remote Commissioning functionality Information about the individual ReMan functions can be found in the Remote Management Specification of EnOcean GmbH Remote Commissioning ReCom The tubular drive supports EnOcean Alliance standardized Remote Commissioning functions Details on these functions are docu mented in the current Remote Commissioning System Specification of the EnOcean Alliance Di...

Страница 21: ... protection IP 44 Min tube inside diameter mm 47 Frequency 868 3 MHz Emission sound pressure level dB A 70 Supported profile Profile no Type Description F6 02 01 RPS Rocker Switch 2 Rocker Light and Blind Control Application Style 1 F6 03 01 RPS Rocker Switch 4 Rocker Light and Blind Control Application Style 1 D2 05 02 VLD Blind Controls for Position and Angle Type 0x02 F6 05 00 RPS Wind Speed Th...

Страница 22: ...ion then continue in the desired direction Tubular drive is overloaded Use a higher torque tubular drive Delete limit positions then reprogram limit positions During the programming run the drive stops short of the limit position to be programmed For safety reasons the drive reacts sensitively to sluggishness during the programming run in order to prevent damage Briefly run curtain DOWN and subseq...

Страница 23: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 23 en ...

Страница 24: ...Declaration of conformity 24 en ...

Страница 25: ...25 ...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ......

Отзывы: