![Baxi LINA 3 COMFORT HT Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/baxi/lina-3-comfort-ht/lina-3-comfort-ht_instruction-manual_2711793057.webp)
57
926.420.3 - EN
INSTRUCTIONS FOR USERS
All the faults are displayed in order of importance; if more than one fault occurs at the same time, the first to be displayed
is the one with higher priority. After eliminating the reasons for the first fault, the second will be displayed, and so on.
If a certain fault occurs frequently, contact the Authorised Service Centre.
9.1 TABLE OF FREQUENT MESSAGES AND FAULTS SHOWN ON THE DISPLAY
To keep the boiler efficient and safe, have it checked by the authorised Service Centre at the end of every operating pe-
riod.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (e.g.: petrol,
alcohol, and so on). Always switch off the appliance before cleaning it (see section 5 Switching off the boiler).
10. ROUTINE MAINTENANCE INSTRUCTIONS
Error
code
Description of fault
Corrective action
10E
External probe sensor faulty
Call the Authorised Service Centre.
20E
NTC delivery sensor faulty
Call the Authorised Service Centre.
28E
NTC fumes sensor faulty
Call the Authorised Service Centre.
50E
NTC domestic hot water sensor faulty
Call the Authorised Service Centre.
60E
Ambient probe faulty
Call the Authorised Service Centre.
62E
Electronic board software version obsolete
Call the Authorised Service Centre.
88E
Communication error between board and AVS 77 climate
controller
Call the Authorised Service Centre.
95E
AVS 77 climate controller clock faulty
Call the Authorised Service Centre.
110E
Safety thermostat tripped
Press
“OK”
twice to reset (figure 1). If this fault persists, call the
Authorised Service Centre.
119E
Hydraulic pressure switch block
Check that the pressure in the system is correct; See section
on filling the boiler. If this fault persists, call the Authorised
Service Centre..
125E
No water in system or Air in system
Press
“OK”
twice to reset (figure 1). If this fault persists, call the
Authorised Service Centre.
127E
“Anti-legionellosis” function enabled
The signal is temporary and finishes automatically when the
function terminates.
130E
Fumes NTC tripped due to overtemperature
Press
“OK”
” twice to reset (figure 1). If this fault persists, call
the Authorised Service Centre.
131E
Electricity has been disconnected from the boiler fol-
lowing fault E125 or E130.
Press
“OK”
twice to reset (figure 1). If this fault persists, call the
Authorised Service Centre.
133E
No gas
Press
“OK”
twice to reset (figure 1). If this fault persists, call the
Authorised Service Centre.
151E
Internal boiler card error
Call the Authorised Service Centre. Check the position of the
ignition electrodes (section 24).
155E
Exceeded max. n° of Reset attempts (n° 5)
Press the
“RESET”
button on the boiler (figure 4).
156E
Input voltage too low
Wait for input voltage to return to normal values. The programme
is reset automatically.
160E
Fan speed threshold not reached
Call the Authorised Service Centre.
193E
Air in circuit
This fault signal is temporary. Reset is performed automati-
cally.
Содержание LINA 3 COMFORT HT
Страница 42: ...42 926 420 3 IT ISTRUZIONI DESTINATE ALL INSTALLATORE HT 1 120 HT 1 240 HT 1 280 CG_2056 0901_1502...
Страница 128: ...128 926 420 3 RU BAXI BAXI 2009 142 EC 92 42 EEC 2004 108 EC 2006 95 EC BAXI S p A CSQ ISO14001 ISO9001 OHSAS 18001...
Страница 131: ...131 926 420 3 RU 3 BAXI CLOW AVS 77 5 12 3 2 3 3 1 0702_2404 4 4 0702_2405 3 2...
Страница 133: ...133 926 420 3 RU 3 4 1 3 1 1 t 1 HW SP 3 4 1 IP PROG 1 3 5 PROG OK OK Day 1 7 IP 3 6 1 4 4 3 6...
Страница 138: ...138 926 420 3 RU 10 10 45 90 02 2 47 47 DD 02 2 45 1 4 4 2 PARTY MAN 60 4 4 1 0703_0507 60...
Страница 140: ...140 926 420 3 RU 8 15 20 5 30 ERROR 9 2 ERROR 2 ERROR 5 AVS 77 155 0703_0904 RESET 4 4 0705_0601 CG_1922 RESET...
Страница 147: ...147 926 420 3 RU 15 4 15 5 0704_1507 L max 15 m 0706_2902 0706_2903 L max 14 m L max 15 m 0706_2904 1 L1 L2 max 80 m 15...
Страница 150: ...150 926 420 3 RU 11 1 a b 11 2 2 11 3 1 2 4 17 17 2 0705_1602 M2 18 3 4 12 0605_1604 M2...
Страница 153: ...153 926 420 3 RU 20 14 AVS 77 16 14 AVS 77 0709_0701 CG_1933 1 AVS 77 1 1 2 3 N...
Страница 158: ...158 926 420 3 RU OK 9 1 110 OK 9 1 90 OK 9 1 0 5 3 5 30 0 5 24 10 24 3 0 1 1 0 23...
Страница 159: ...159 926 420 3 RU 24 25 2 2 18 020429_0300 21 OF 555 0 OF 555 0 1 15 15 OF 555 0 0 25 1 17 CG_2190 0911_1201...
Страница 164: ...164 926 420 3 RU 1 setpoint setpoint setpoint setpoint AMBON RMOD AMBON RMOD T AMBON RMOD EXT T 0 0 1 1 1 1 0...
Страница 167: ...167 926 420 3 RU 0901_1506 CG_1934B 32 N R G V B V HT 280 HT 330 NTC RESET NTC...
Страница 168: ...168 926 420 3 RU 0901_1503 CG_2056 HT 1 120 HT 1 240 HT 1 280 N R G V B V RESET NTC...
Страница 340: ...340 926 420 3 EL GR BAXI CE 2009 142 92 42 2004 108 2006 95 S p A CSQ ISO9001 ISO14001 OHSAS18001 BAXIS p A...
Страница 344: ...344 926 420 3 EL GR 4 2 3 1 2 COOL 31 COOL 31 3 2 COMFORT 3 6 ff 3 3 25 25 50 50 75 75 100...
Страница 345: ...345 926 420 3 EL GR 3 4 1 3 1 1 C tAMB 1 C HW SP C 3 4 1 IP PROG 1 OK OK Day 1 7 3 5 PROG 3 6 1 4 4 3 6...
Страница 350: ...350 926 420 3 EL GR 10 10 45 90 HH 02 2 47 47 DD 02 2 45 1 0703_0507 60 4 4 2 PARTY MAN MM 60 4 4 1 AMB...
Страница 352: ...352 926 420 3 EL GR 8 5 C 30 C ERROR E 9 2 ERROR 2 reset RESET AVS 77 0703_0904 155E RESET 4 4 0705_0601 CG_1922 RESET...
Страница 362: ...362 926 420 3 EL GR E 11 1 a b 11 2 M2 3 1 2 4 C 17 17 2 0705_1602 M2 18 3 4 12 0605_1604 M2...
Страница 365: ...365 926 420 3 EL GR 20 14 0709_0701 CG_1933 1 AVS 77 AVS 77 16 14 AVS 77 1 1 2 3 N...
Страница 370: ...370 926 420 3 EL GR OK 9 1 NTC 110 C OK 9 1 90 C OK 9 1 0 5 bar 3 5 C 30 C 24 10 24 3 bar 0 23...
Страница 371: ...371 926 420 3 EL GR 24 25 O2 CO2 CO 18 020429_0300 21 OF 555 0 OF 555 0 1 15 OF 555 0 0 25 1 17 CG_2190 0911_1201...
Страница 376: ...376 926 420 3 EL GR AMBON RMOD EXT T AMBON RMOD EXT T 0 0 COMFORT 1 1 1 1 0...
Страница 379: ...379 926 420 3 EL GR 0901_1506 CG_1934B 32 C M N R G V B G HT 240 HT 280 HT 330 NTC NTC RESET NTC FASTON...
Страница 380: ...380 926 420 3 EL GR 0901_1503 CG_2056 HT 1 120 HT 1 240 HT 1 280 BOILER C M N R G V B G NTC NTC RESET FASTON...
Страница 382: ...382 926 420 3 EL GR...
Страница 383: ...383 926 420 3 EL GR...