ISI34, ISI35
8
www.baumer.com
Model
Operating mode
Inputs
INP A
INP B
ISI34.010AX01
ISI34.011AX01
ISI34.013AX01
ISI35.010AX01
ISI35.011AX01
ISI35.013AX01
Timer
––
0
0 ... 0,7 V DC
Timer
––
10 ... 260 V AC/DC
0
4 ... 30 V DC
10 ... 260 V AC/DC
0
0 ... 0,7 V DC
0
4 ... 30 V DC
10 ... 260 V AC/DC
DC operating modes:
Timer:
INP A:
no function
INP B:
Timer-Enable-Input
AC operating modes:
Timer:
INP A:
Timer-Enable-Input AC/DC
INP B:
reset input AC/DC
Table 1
Time range
99999h 59 m/
99999.99 h
9999 h 59 m 59 s/
9999999.9 s
10 ... 260 V AC/DC
NPN
PNP
AC/DC
NPN
PNP
AC/DC
AC/DC
AC/DC
Options:
x = A: no backlight
x = B: with backlight
Main technical features:
Display:
LCD, 8 decades, height of the figures 8 mm
Display range:
0 ... 99999999 with leading zeros
suppression.
Accuracy:
< 100 ppm
Note:
For one ON/OFF-cycle the counter can lose
max. one impulse of the selected time
range
Overflow:
In case of a display range overflow, the
timer starts again from 0, but without
removing the leading zeros and activating
all decimal points.
Keys:
Electrical locking of the reset key
Housing:
Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2
+0,3
x 45
+0,6
mm
Mounting depth:
approximately 48 mm
Weight:
approximately 50 g
Protection level:
IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm
2
2 x 0,75 mm
2
AWG 26-14
EMC:
Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Device safety:
Design to:
EN61010 Part 1
Protection Class:
2
Application area:
Soiling Level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately. 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 .. +70°C
Altitude:
to 2000 m
Backlighting:
must be powered by an external elecrical
source (24 V ±20%, 50 mA)
Overview
1.10 Failure possibilities and causes
Impossible to use the keys:
- Key lock input activated
Counter does not count:
- Wrong or reversed wiring of the counting input
- Setting of an input signal not matching the pulse generator
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator and the
counter
- Signal levels do not reach the switching threshold of the counter
If, despite all, your device still does not operate, contact your
local representative or call us directly for technical support.
When sending your device back, please attach a short descrip-
tion of the failure, of the programming and of the connection
diagram, in order to allow us to reproduce a possibly existing
defect and to repair your device as quickly as possible.