AUBER INSTRUMENTS
WWW.AUBERINS.COM
2021.03 P1/5
JSL-64A 1/32 DIN General Purpose Timer
Version 1.2 (March 2021)
1.
Overview
This JSL-64 timer can count from 0.01 second to 9999 minutes. Operating
function modes include single delay, double delay, and cycle delay. It can
count-down or count-up. The timer can be activated automatically when
powering up, by front key pad, or via remote switch.
2. Specification
Timer range: 0.01 second to 9999 minutes.
Timer mode: single delay, double delay, cycle delay, count-up timer.
Timer trigger: power on, front key pad, or remote switch.
Timer error: < 1 s/day.
Power supply: 85 - 260 V AC or DC.
Power consumption: < 2 W.
Relay output: 10A at 240 VAC / 30 VDC (resistive load)
Average relay life: 100,000 times at rated current.
Operating temperature: 0 - 60° C.
Humidity: 0 - 95% RH.
Panel cutout: 22 x 45 mm.
Outer dimension: 24 x 48 x 75 mm (1" x 2" x 3").
3.
Front
Panel
Figure1. Front panel.
1. Time unit indicator (colon sign): Turns on when time format is MM:SS
(Minutes: Seconds) or HH:MM (Hours: Minutes) and flashes when the timer is
running; turns off when time unit is M (Minutes) or S (Seconds).
2. LED digital display: During normal operation as a timer, it displays the actual
time. When timer is stopped, it displays the preset value. During controller
setup, it displays parameter value.
3.
OUT
indicator: Turns on when relay is on; turns off when relay is off.
4.
RUN
indicator: Turns on when timer is running; blinking/flashing when timer
is paused; turns off when timer is stopped.
5.
SET
key: press it once to set timer and relay delay timer T1/T2 (if applicable.
T1 timer shows as t-1, T2 timer shows as t-2); press and hold it for 3 second
will enter the programming mode. This key is disabled when timer is running.
6.
DOWN
key / STP key: Reduces the value in the programming mode; when
the timer is running, press it to stop the timer. (For special stop function in
single delayed on mode, please see note 6 on page 3 for details).
7.
UP
key / PAU key: Increases the value in the programming mode; when
timer is running, press and hold it will pause the timer; the timer will continue
running after this key is released.
8.
RST
key: Reset key. When the timer is running, press it will restart the timer.
If "RUN" parameter is set to RST, press it will start the timer after powered up.
4. Terminal Assignment
6
7
8
9
10
1
2
3
4
5
OUT
ST
STP
PAU
RST
COM
AC
85~260V
Figure 2. Terminal assignment.
Pin #
Function
Description
Note
Note: pin 1 to pin 5 are high voltage pins.
1
AC power input
85V ~ 260V AC power input.
2
AC power input
3
N.C.
Not connected.
4
Relay Output
Normally open (NO) relay. The relay
action is in synchronize with the OUT
indicator.
A
5
Relay Output
Note: pin 6 to pin 10 are low voltage pins.
6
Reset
When connected with COM pin,
works as the RST key to reset the
timer.
B
7
Pause
When connected with COM pin,
works as the PAU key to pause the
timer.
B
8
Stop
When connected with COM pin,
works as the STP key to stop the
timer.
B
9
Special
Terminal
Special terminal reserved for
Espresso Shot Timer (EST) function.
C
10
Common
Common pin.
B
Note A
. Terminal 4 and 5 are for normally-open (NO) relay output. When this
relay is energized (or when the OUT LED is on), pin 4 is connected to pin 5
internally; When the relay is NOT energized (or when the OUT LED is off), pin
4 is disconnected from pin 5
. The relay is a “dry switch” that does not provide
power by itself. Please see the wiring examples in Section 7.
Instruction Manual
1
4
5
6
7
8
2
3