AUBER INSTRUMENTS
WWW.AUBERINS.COM
2021.03
P3/5
6. Parameter Settings
All parameters are listed in the table below.
Press and hold SET key for 3 seconds to enter the menu mode. For each
parameter setting, use UP or DOWN key to select different programming
values. Press SET key to confirm then exit. Please check figure 3 for details.
For the definition of each programming value, see Table 1.
Table 1. Parameter Description.
Code
Description
Range
Initial
No
te
Set Values
(Short-press SET key)
T1
T1
Set value for T1
1
:
10
1
T2
T2
Set value for T2
1
.
10
2
Parameters
(Long-press SET key for 3 seconds)
FUNC
Func
Timer function, operating
mode
SDL,
DINT,
CYCL,
EST *
sdl
3 *
T1U
T1u
T1 timer unit
S,
M:S,
M,
H:M
M
:
S
4
T2U
T2u
T2 timer unit
S
TDIR
Tdir
Timer counting direction
UP, DN
DN
5
OUT
Out
Relay output mode
OFDL,
ONDL
OFDL
6
RUN
run
Timer triggering action
RST, PU
RST
7
STOP
stop
Relay action when STP
key is pressed
0, 1
0
8 **
PAUS
paus
Relay action when PAU
key is pressed
0, 1
1
9
* Please note that ESP function is a new feature added to JSL-64A. It is not available in
JSL-64.
** Please note that STOP parameter will only appear in the menu when FUNC = SDL
and OUT = ONDL.
Details about each parameter
Note 1
.
T1
is the set value in Single Delay (
SDL
) mode. It is also the first set
value in in Delayed Interval Mode (
DINT
) and the Cycled Mode (
CYCL
) mode.
Note 2.
T2
is the second set value in Delayed Interval Mode (
DINT
) or in the
Cycled Mode (
CYCL
). This parameter will only be displayed if the Timer Mode
FUNC
is set to either
DINT
or
CYCL
mode.
Note 3: FUNC
is the timer operating mode, it can be set to
SDL
,
DINT
,
CYCL
,
or
EST
.
SDL
(Single Delay)
:
The timer counts a single period of time that is
defined in
T1
. The relay can either be turned on during this period of timer or it
can be turned on at the end of this period of time, depends on the
OUT
setting.
When
OUT
=
OFDL
, the relay turns on at the beginning when timer starts
counting, and turns off when the counting stops. When
OUT
=
ONDL
, the relay
stays off when timer starts counting, and the relay turns on when the timer
reaches the set value till the RST (reset) key is pressed or when the power to
the device is cycled. Please refer to Note 6 for details about
OUT
parameter.
In Single Delay and On-Delay mode (i.e.,
FUNC
=
SDL
,
OUT
=
ONDL
), a
special parameter
“
STOP
”
will appear in the parameter menu. For details
please refer to the Note 8 below.
DINT
(Delayed Interval): The timer will count time for two periods of time,
T1
and
T2
, and then stops. Relay action depends on the
OUT
setting. When
OUT
=
OFDL
, the relay turns on at the end of T1, stays on during T2 time, and
then turns off at the end of T2 time. When
OUT
=
ONDL
, the relay turns on at
the beginning at T1 time, turns off at the end of T1 time, stays off during T2,
and then turns on again at the end of T2 time. This is a single action process.
CYCL
(Cycle): The timer will repeat a counting cycle that consists of two
periods of time, T1 and T2. The relay turns on/off during each cycle depending
on the OUT setting. When
OUT
=
OFDL
, the relay turns on at the end of T1,
stays on during T2 time, and then turns off at the end of T2 time. When
OUT
=
ONDL
, the relay turns on at the beginning at T1 time, turns off at the end of T1
time, stays off during T2, and then turns on again at the end of T2 time. This
cycle will be immediately repeated till it is stopped or reset.
EST
(Espresso Shot Timer): This is a special mode designed for counting
the shot time (brew time) on an espresso machine. The timer display resets to
zero and it starts counting up when the pin 9 and 10 are shorted together. The
timer stops counting when terminal 9 and 10 are disconnected. The time unit is
determined by the parameter
T1U
. Pressing the RST key can clear the display.
The relay output, STP key, and PAU key are not functional in this mode. The
settings of parameter T2U, TDIR, OUT, RUN, STOP, and PAUS are irrelevant
to this mode.
Note 4. T1U
and
T2U
define the time unit for
T1
and
T2
. (Note, T2 is only
available when
FUNC
=
DINT
or
CYCL
).
Settings Description
Range
S
Seconds
0.01 s ~ 99.99 s
M:S
Minutes: Seconds
1 s ~ 99 m 59 s
M
Minutes
1 m ~ 9999 m
H:M
Hours: Minutes
1 m ~ 99 h 59 m
Note 5
.
TDIR
determines the Timer Counting Direction.
UP
: counting up.
DN
: counting down.
Note 6
.
OUT
determines the relay output status as the timer runs.
OFDL
(off-delay): the relay will turn ON when timer starts counting and
the relay will turn OFF when the timer reaches the set value.
ONDL
(on-delay): the relay will stay OFF when the timer starts counting
and the relay will turn ON when the timer reaches the set value.
Note 7
.
RUN
determines how does the timer start counting.
PU
(power up): the timer starts counting when the device is powered up.
RST
(reset): the timer starts when reset button is pressed and released.