Note B.

 Pin 10 is the common pin for the pin 6/7/8. There are two ways to 

operate terminal 6, 7, and 8. 
 

a)

 Connecting a normally open (NO) momentary push button switch between 

the pin (6, 7 or 8) to the COM (10). Please note, the function starts when you 
release (or open) the button of the switch, not when you press down the switch. 
See Figure 5. 
 

b)

 

Connecting a DC logic signal (TTL or CMOS or voltage in the range from 3 

to 30 VDC) between the terminal (

6, 7 or 8

) to the COM (10). Please note, the 

function is rising-edge triggered. The logic signal should normally be at high 
level. The function starts when the signal goes from low to high. If you have an 
inverted logic signal, you need to connect a NPN transistor between terminal 
and COM; add 10Kohm resistor to the gate for signal input.

 See Figure 6.  

 
The function of all these terminals is accomplished by the rising phase of 
control signal. If the control signal is from a momentary NO switch that is 
connected to the terminal, the action starts when switch is released (from close 
to open). When the control signal is from another digital device, the action 
starts when voltage goes from low to high.  
 

Note C

. Pin 9 is a special terminal reserved for Espresso Shot Timer function 

(when FUNC is set to EST) in the JSL-64A and JSL-64A-EST. When it is 
connected with the COM pin, the timer resets its display and start counting up 
from zero. When it is disconnected from COM pin, the counting stops.   
 
 

5. Getting Started 
5.1 Powering up the timer 

To power up the timer, simply connect 120 VAC or 220 VAC power to pin 1 
and 2. It is recommended to use a power supply or power cord that has an 
ON/OFF switch on it.  
 

5.2 General operations 

A brief description of the keys on the timer are described below. Please also 
refer to Section 6 for details of parameter 

RUN

STOP

, and 

PAUS

. The 

settings of these parameters can affect the actual functions of STP, PAU, and 
RST key.  
 
 

Key 

Action 

SET 

 

Shot-press: bring up the set value; select parameter; save 
value.   

 

Long-press: bring up the parameter menu.   

 

No action while timer is running.  

▼/STP

 

 

Stops the timer from counting time.  

 

May stops the relay output depending on the STOP setting.   

 

Decrease value.  

▲/PAU

 

 

Pauses the timer counting.  

 

Increase value.  

RST 

 

Clears timer display.  

 

May restart the timer if parameter RUN = RST. 

 
 

5.3 Accessing the parameters 

To bring up the parameter menu, long press the SET key for 3 seconds till the 

display shows “

FUNC

”. 

Use UP or DOWN arrow key to scroll the parameter list. 

Use SET key to select or check the value of a parameter. Use UP or DOWN 
arrow key to change the value of any parameter, and press the SET again to 
save the new value then go back to the parameter list.  
 
Please refer to the Section 6 for the details of each parameter. Figure below 
shows how to access the menu.  
 
 

 1

:

10

FUNC

M

s

sdl

T1u

END

SET

Long-press 

for 3 

seconds

SET

EST

SET

SET

s

Set Value 

(blinking)

Change the set value 

using UP or DOWN 

arrow key

Normal Display 

Mode

 

Figure 3. Flow chart of how to change the parameter values. 

 
 

5.4 Changing the set values 

Depending on the timer function you choose, you may need to adjust the set 
values 

T1

 and 

T2

.   

 
If you use the Single Delay function (

FUNC

 = 

SDL

), you’ll need to adjust 

T1

. If 

you use Delayed Interval or Cycle function (

FUNC

 = 

DINT

 or 

CYCL

), you’ll 

need to adjust 

T1

 and 

T2

. If you use the Espresso Shot Timer function (

FUNC

 

EST

), you don’t need to adjust the set values. The flow chart below shows 

how to adjust the set values.  
 

 1

:

10

T1

 1

:

10

END

SET

Short-press

SET

1

:

00

SET

Set Value 

(blinking)

Change the set value 

using UP or DOWN 

arrow key

Normal Display 

Mode

 

Figure 4. Flow chart of how to change set values on the timer. 

 

 

Содержание JSL-64A

Страница 1: ...d hold it for 3 second will enter the programming mode This key is disabled when timer is running 6 DOWN key STP key Reduces the value in the programming mode when the timer is running press it to stop the timer For special stop function in single delayed on mode please see note 6 on page 3 for details 7 UP key PAU key Increases the value in the programming mode when timer is running press and hol...

Страница 2: ...f the keys on the timer are described below Please also refer to Section 6 for details of parameter RUN STOP and PAUS The settings of these parameters can affect the actual functions of STP PAU and RST key Key Action SET Shot press bring up the set value select parameter save value Long press bring up the parameter menu No action while timer is running STP Stops the timer from counting time May st...

Страница 3: ... a special parameter STOP will appear in the parameter menu For details please refer to the Note 8 below DINT Delayed Interval The timer will count time for two periods of time T1 and T2 and then stops Relay action depends on the OUT setting When OUT OFDL the relay turns on at the end of T1 stays on during T2 time and then turns off at the end of T2 time When OUT ONDL the relay turns on at the beg...

Страница 4: ...U key is pressed When PAUS 0 pressing the PAU key will only pause the timer and it will NOT affect the relay output status When PAUS 1 pressing the PAU key will not only pause the timer but also change a relay output status from ON to OFF However it will not affect relay status if the relay is OFF 7 Wiring Examples 1 Signal controlled by switches Power 120 or 240V AC is sent to pin 1 and 2 The ext...

Страница 5: ...be triggered when stop key switch is released voltage from low to high Power Relay output Reset Pause Stop T1 Ta Tb Ta Tb T1 Figure 10 a Single delay and off delay FUNC SDL OUT OFDL Power Relay output Reset Pause Stop 0 T1 Ta Tb Ta Tb T1 Stop 1 Figure 10 b Single delay and on delay FUNC SDL OUT ONDL for the STOP parameter please see Note 8 on page 2 for details Power Relay output Reset Pause Stop ...