Baumer_GIM500R_CANopen_MA_EN.docx
7/29
www.baumer.com
03.19
3.3.2
CANopen message structure
The first part of a message is the COB ID (Identifier).
Structure of the 11-bit COB ID:
Function code
Node ID
4-bit function code
7-bit node ID
The function code provides information on the type of message and priority
The lower the COB ID, the higher the priority of the message
Broadcast messages:
Function code
COB ID
NMT
0
SYNC
80h
Peer to peer messages:
Function code
COB ID
Emergency
80h + Node ID
PDO1 (tx)
1)
180h + Node ID
PDO2 (tx)
1)
280h + Node ID
SDO (tx)
1)
580h + Node ID
SDO (rx)
1)
600h + Node ID
Heartbeat
700h + Node ID
LSS (tx)
1)
7E4h
LSS (rx)
1)
7E5h
1): (tx) and (rx) from the viewpoint of the sensor
The node ID can be freely selected by means of the CANopen bus between 1 and 127.
The sensors are supplied with the Node ID 1 and baud rate 50 kBit/s.
This can be changed with the service data object 2101h or object 2100h or using LSS.
A CAN telegram is made up of the COB ID and up to 8 bytes of data:
COB ID DLC
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Xxx
x
xx
xx
xx
xx
xx
xx
xx
xx
The precise telegram is outlined in more detail at a later point.