Baumer_GIM500R_CANopen_MA_EN.docx
22/29
www.baumer.com
03.19
3.4.1
Communication Parameter (CiA DS-301, CiA DS-302 Part 2)
Object
Sub-Index
Name
Format
Access
Default
Save
1000h Device Type
U32
ro
102019Ah
1001h Error Register
U8
ro
0h
1002h Manufacturer Status register
U32
ro
0h
1003h PreDefined ErrorField
00h Maximum Subindex
U8
rw
0h
yes
01h Latest entry
U32
ro
.. ..
..
..
..
05h Oldest entry
U32
ro
1005h Sync COB-ID
U32
rw
80h
yes
1008h DeviceName
VSTR
ro
GIM500
1009h Hardware Version
VSTR
ro
1.00
or higher
100Ah Software Version
VSTR
ro
1.00
or higher
1010h Store Parameters
00h Maximum Subindex
U8
ro
4h
01h Save all parameters
U32
rw
02h Communication parameters
U32
rw
03h Application parameters
U32
rw
04h Manufacturer- specific parameters
U32
rw
1011h Restore Default Parameters
00h Maximum Subindex
U8
ro
4h
01h Restore all parameters
U32
rw
02h Restore communication parameters
U32
rw
03h Restore application parameters
U32
rw
04h Restore manufacturer specific parameters
U32
rw
1014h Emergency COB-ID
U32
rw
80h + Node-ID
yes
1016h Consumer heartbeat time
yes
00h Maximum Subindex
U8
ro
1h
01h Consumer heartbeat time
U32
rw
10000h
yes
1017h Producer Heartbeat Time
U16
rw
0h
yes
1018h Identity Object
00h Maximum Subindex
U8
ro
4h
01h VendorID
U32
ro
ECh
02h Product Code
U32
ro
40h
03h Revision Number
U32
ro
Works-defined
yes
04h Serial Number
U32
ro
Works-defined
yes
1800h Transmit PDO1 Parameter
00h Maximum subindex
U8
ro
5h
01h COB-ID
U32
rw
180h+id
yes
02h PDO Type
U8
rw
FFh
yes