3.4.2.1
Baud rate (2100h)
The baud rate can be changed and read through this object (Additionally to LSS). The following parameters
are possible:
Baud rate (2100h)
Value
Description
2
50kBaud
3
100kBaud
4
125kBaud
5
250kBaud
6
500kBaud
7
800kBaud
8
1000kBaud
The new baud rate will take effect after a restart. 10kBaud is not supported.
3.4.2.2
Node-ID (2101h)
The Node-ID can be changed and read through this object (Additionally to LSS). The parameters are possible:
Node-ID (2101h)
Value
Description
1..127
Node-ID
The new Node-ID will take effect after a restart.
3.4.2.3
Axis Alignment (2106h)
By accessing this object a change of the device orientation can be done (swapping sign and switch axes). A
change of the default orientation can lead to a loss of accuracy and is not suggested.
Axis mapping (subindex 1)
The axes can be switched as shown in the following tables:
Bit Mask:
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
Mapped Z Axis
Mapped Y Axis
Mapped X Axis
Default
-
10
01
00
Possible values:
Value (bit) Axis
00
X-Axis
01
Y-Axis
10
Z-Axis
11
Invalid
Axis sign (subindex 2)
Bit Mask:
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
Z-Axis
Y-Axis
X-Axis
Default
-
0
0
0
Possible values:
Value (bit)
Sign
0
Positive
1
Negative