Baumer_GIM500R_CANopen_MA_EN.docx
28/29
www.baumer.com
03.19
3.5
LED status display
The LED status display is according to DS-303 Part 3 V1.0.0 with some exceptions. The following defined
LED behaviors are overwritten by the application in case of a severe internal error.
3.5.1
CANopen Status LED (Green)
Status LED
State
Description
Single flash
STOPPED
The Device is in STOPPED state
Blinking
PREOPERATIONAL
The Device is in the PRE-
OPERATIONAL state
On
OPERATIONAL
The Device is in the
OPERATIONAL state
Off
Power off
The Device is not powered
3.5.2
CANopen Error LED (Red)
Error LED
State
Description
Single flash
Bus warning
The CAN controller is not
receiving ACK messages (i.e. no
master)
Off
No error
The Device is in working
condition
On
Bus off / Internal Error
The CAN controller is bus off or
an internal error is present.