9
|
Diagnostic data
Baumer
46
Operating Manual
OM20/ OM30 RS485 with Modbus RTU | V1
Exposure reserve
In each measurement, a value is recorded for the exposure reserve.
As the exposure reserve is always described by a fixed value range, the following information
has a fixed value:
n
Start of valid range: 0
n
End of valid range: 100
n
Number of intervals/bins: 20
This yields:
1 interval covers a value range of 5.
Example:
The object to be measured is outside the measurement range for 5 measurements. Therefore,
the sensor records an exposure reserve of 0. This results in the following distribution:
Bin
Value range min.
Value range max.
Number of
measurements
Bin 1
0
< 5
5
Bin 2
5
< 10
0
Bin 3
10
< 15
0
Bin 4
15
< 20
0
Bin 5
20
< 25
0
...
...
...
...
Example of a recorded exposure reserve histogram: