Baumer
Functions
|
8
OM20/ OM30 RS485 with Modbus RTU | V1
Operating Manual
41
Modbus RTU command – holding register: teach button
Address 411 – Teach Lock:
Address
Access
Number of
registers
Data type
Description
411
Read/write
1
uint8_t
Time until the Teach button is deac-
tivated:
n
Minimal – Teach button is con-
tinuously active: 0
n
Maximal – Teach button is con-
tinuously inactive: 0xFF
Address 412 – Teach Pattern:
Address
Access
Number of
registers
Data type
Description
412
Read/write
1
uint8_t
Parameterize mode of the teach but-
ton:
n
0 =
Xpert
n
1 =
Xpress
Also see about this
2
8.12
Switching the laser on and off
INFO
The laser continues to flash very weakly when switched off. This keeps the laser element at op-
erating temperature so that it is fully functional when it is switched on again.
The laser can be switched on and off again, for example, for maintenance of the system.
Modbus RTU command – holding register: laser
Address 410 – Laser On/Off:
Address
Access
Number of
registers
Data type
Description
410
Read/write
1
uint16_t
Status of the laser:
n
0 = off
n
1 = on
Содержание 11233538
Страница 1: ...V1 3 16 2021 EN US Operating Manual Laser distance sensors OM20 OM30 RS485 with Modbus RTU...
Страница 53: ......