OM20/ OM30 RS485 with Modbus RTU | V1
Operating Manual
13
3.5
Modbus RTU
Modbus RTU is a standardized protocol that is based on a serial master/slave communication
via RS485 in this case.
The functionality of the sensor can be accessed by reading or writing entries in the tables
Dis-
crete Inputs
,
Input Registers
, and
holding registers
. The following Modbus function codes (FC)
are supported:
n
Read Discrete Inputs (FC 02)
n
Read Input Registers (FC 04)
n
Read Holding Registers (FC 03)
n
Write Single Holding Register (FC 06)
n
Write Multiple Holding Registers (FC 16)
Below you will find an overview of the available registers. The 2 described tables are indepen-
dent of each other, so that the same address can represent different functions in different ta-
bles. The number of registers to be read or written with a Modbus command must correspond to
the length specified for the respective sensor functionality. A partial reading or writing of param-
eters is not possible.
INFO
1 Modbus register corresponds to 2 bytes. If the data type of a sensor parameter is wider than a
2 byte Modbus register, the parameter is divided among several Modbus registers. The less sig-
nificant bits are located at the smaller address and the more significant bits at the larger ad-
dress (Little Endian).
As a general rule, all registers can be written and read. If a register is read that is only intended
for write access, 0xFFFF is returned.
Holding register: function ID 03/06/16
Address
Number of
registers
Command
Description
101
1
Precision
Select signal filtering
102
1
Custom Median Filter
Length
Configurable filter length – median filter
103
1
Custom Average Filter
Length
Configurable filter length – average filter
180
2
Zero Position
Set zero position numerically
185
1
Zero Position Teach
Teach zero position
200
2
Distance Near
Set measuring range limit (near)
202
2
Distance Far
Set measuring range limit (far)
220
1
Meas Range To Max
Maximize measurement range
300
2
Switch Point 1
Far threshold of the switching output
302
2
Switch Point 2
Near threshold of the switching output
304
2
Switch Mode
Select switching mode
306
2
Hysteresis Width
Hysteresis
308
1
Polarity
Polarity of the switching output