3
|
Description
Baumer
14
Operating Manual
OM20/ OM30 RS485 with Modbus RTU | V1
Address
Number of
registers
Command
Description
400
2
Trigger Mode
Configure trigger mode
402
2
Fix Time Trigger Interval
Time period for
Interval
trigger mode
410
1
Laser ON/OFF
Switch laser on and off
411
1
Teach Lock
Time until the Teach button is deactivated
412
1
Teach Pattern
Parameterize the mode of the Teach but-
ton
503
1
Sensor Reset
Reset the sensor to the factory settings
800
1
Dropout Timeout
Holding time for invalid measured value
1000
1
Reset All Statistics
Reset all statistical data (operating time,
histograms)
1001
1
Reset Operation Time
Reset operating time
1002
1
Reset Distance Histogram
Reset histogram for distance
1003
1
Reset Exposure Reserve
Histogramm
Reset the histogram for exposure reserve
1050
16
App Specific Tag
Customer-spec. identification of the sen-
sor
1066
16
Function Tag
Customer-spec. identification of the sen-
sor
1082
16
Location Tag
Customer-spec. identification of the sen-
sor
1100
1
Modbus Slave Address
Slave address
1101
1
Modbus Baudrate ID
Baud rate
1102
1
Orange LED function
Parameterize function of the LED
Input register: function ID 04
Address
Number of
registers
Command
Description
0
16
Vendor Name
Manufacturer name
16
16
Vendor Text
Manufacturer note
32
26
Product Name
Product name
58
5
Product ID
Item number
63
32
Device Text
Product text
95
10
Serial Number
Serial number
105
5
Hardware Revision
Hardware version
110
5
Firmware Revision
Firmware version
115
6
P-Code
Production code
200
13
All Measurement Values
Measured value and additional information
301
2
Operation Time: Powerup
Operating time since the sensor powered
up
303
2
Operation Time: Resetable Operating time since a defined point in
time
Содержание 11233538
Страница 1: ...V1 3 16 2021 EN US Operating Manual Laser distance sensors OM20 OM30 RS485 with Modbus RTU...