8
|
Functions
Baumer
42
Operating Manual
OM20/ OM30 RS485 with Modbus RTU | V1
8.13
Resetting the sensor
The sensor can be reset to the factory settings (see
).
Modbus RTU command – holding register: factory reset
Address 503 – Sensor Reset:
Address
Access
Number of
registers
Data type
Description
503
Write
1
x
Reset the sensor to the factory set-
tings: Call up the function by writing
any number.
8.14
Individual sensor identification
You have the option of giving the sensor various individual identifiers in order to uniquely iden-
tify the sensor. An identification of the sensor can be stored in relation to the application, the
function, or the place of use as well.
Modbus RTU command – holding register: identification
Address 1050 – App Specific Tag:
Address
Access
Number of
registers
Data type
Description
1050
Read/write
16
STRING[]
Enter use of the sensor.
Address 1066 – Function Specific Tag:
Address
Access
Number of
registers
Data type
Description
1066
Read/write
16
STRING[]
Enter function of the sensor.
Address 1082 – Location Tag:
Address
Access
Number of
registers
Data type
Description
1082
Read/write
16
STRING[]
Enter location of the sensor.