Configuring the Camera
Basler A400k
4-25
DRAFT
Digital Shift CSR
Area of Interest Starting Column CSR
Register Base Address:
0x1900
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in this register is set out of range
Field Name:
Mode
Offset:
0x0001
Size:
1 Byte
Type:
Read / Write
Description:
Writing an integer value to this field enables/disables digital shift:
0x00 = No digital shift
0x01 = Digital shift once (multiplies output 2X)
0x02 = Digital shift twice (multiplies output 4X)
See Section
for more information about digital shift and precautions you must consider.
Register Base Address:
0x1040
Field Name:
Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in this register is set out of range
0X81 = The setting for the AOI starting column conflicts with the setting for the AOI width
Field Name:
Starting Column
Offset:
0x0001
Size:
2 Bytes
Type:
Read / Write
Description:
Writing an integer value to this field sets the starting column for the area of interest (AOI)
feature. The value for the starting column can normally range from column 1 (0x0000) to
column 2336 (0x0920). Starting columns can only be selected in increments of 16 (+1), that
is, the starting column can be 1, 17, 33, and so on. The actual available range may be lim-
ited by the way any related parameters are set.
If the value is set to 1, the starting column in the AOI will be column 1. If the value is set to
17 the starting column in the AOI will be column 17. Etc.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the starting column value
Byte 2 = High byte of the starting column value
See Section
for more information about the AOI feature.
Field Name:
Min
Offset:
0x0003
Size:
2 Bytes
Type:
Read only
Description:
Minimum allowed integer value for the starting column setting. This field is updated to re-
flect limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = High byte of the min value
Содержание A400K
Страница 1: ...Basler A400k USER S MANUAL Document Number DA00062410 Release Date 27 September 2007 ...
Страница 4: ......
Страница 25: ...Camera Interface Basler A400k 2 9 DRAFT Figure 2 5 A402k Camera Frame Grabber Interface ...
Страница 26: ...Camera Interface 2 10 Basler A400k DRAFT Figure 2 6 A403k Camera Frame Grabber Interface ...
Страница 27: ...Camera Interface Basler A400k 2 11 DRAFT Figure 2 7 A404k Camera Frame Grabber Interface ...
Страница 52: ...Camera Interface 2 36 Basler A400k DRAFT ...
Страница 154: ...Configuring the Camera 4 54 Basler A400k DRAFT ...
Страница 168: ...Troubleshooting 6 10 Basler A400k DRAFT ...
Страница 172: ...Feedback iv Basler A400k DRAFT ...
Страница 176: ...Index viii Basler A400k DRAFT ...