Configuring the Camera
Basler A400k
4-27
DRAFT
Area of Interest Width in Columns CSR
Register Base Address:
0x1020
Field Name:
Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in this register is set out of range
0X81 = The setting for the AOI starting column conflicts with the setting for the AOI width
Field Name:
Width
Offset:
0x0001
Size:
2 Bytes
Type:
Read / Write
Description:
Writing an integer value to this field sets the width in columns for the area of interest (AOI)
feature. The value for the width in columns can normally range from 16 (0x0010) to 2352
(0x0930). The width can only be selected in increments of 16, that is, the width can be 16,
32, 48, and so on. The actual available range may be limited by the way any related pa-
rameters are set.
If the value is set to 16, the length of the AOI will be 16 columns. If the value is set to 32,
the width of the AOI will be 32 columns. Etc.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the length value
Byte 2 = High byte of the length value
See Section
for more information about the AOI feature.
Field Name:
Min
Offset:
0x0003
Size:
2 Bytes
Type:
Read only
Description:
Minimum allowed integer value for the width setting. This field is updated to reflect limita-
tions caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = High byte of the min value
Field Name:
Max
Offset:
0x0005
Size:
2 Bytes
Type:
Read only
Description:
Maximum allowed integer value for the width setting. This field is updated to reflect limita-
tions caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = Mid byte of the max value
Field Name:
Increment
Offset:
0x0007
Size:
2 Bytes
Type:
Read only
Description:
An integer value indicating the increment for the width setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = Mid byte of the max value
Содержание A400K
Страница 1: ...Basler A400k USER S MANUAL Document Number DA00062410 Release Date 27 September 2007 ...
Страница 4: ......
Страница 25: ...Camera Interface Basler A400k 2 9 DRAFT Figure 2 5 A402k Camera Frame Grabber Interface ...
Страница 26: ...Camera Interface 2 10 Basler A400k DRAFT Figure 2 6 A403k Camera Frame Grabber Interface ...
Страница 27: ...Camera Interface Basler A400k 2 11 DRAFT Figure 2 7 A404k Camera Frame Grabber Interface ...
Страница 52: ...Camera Interface 2 36 Basler A400k DRAFT ...
Страница 154: ...Configuring the Camera 4 54 Basler A400k DRAFT ...
Страница 168: ...Troubleshooting 6 10 Basler A400k DRAFT ...
Страница 172: ...Feedback iv Basler A400k DRAFT ...
Страница 176: ...Index viii Basler A400k DRAFT ...