Troubleshooting
6-4
Basler A400k
DRAFT
Check the setup on your frame grabber
and make sure that the ExSync signal is
not too short. The period of the ExSync
signal must not be lower than shown in
.
(On many frame grabbers, the period of
the ExSync signal is adjusted by
changing a setting for the “frame rate”.
Your frame rate should not exceed the
Is the ExSync period OK?
Yes
No
Correct
the
settings.
Check your exposure setting.
The exposure time must be
less than the ExSync period.
Is the exposure OK?
Switch on test image one.
Can the test image be seen?
Correct
the
setting.
Go to the
interfacing
troubleshooting
chart.
Replace the camera.
No
No
Yes
Are you controlling the camera with
an ExSync signal or is the camera
in free-run?
ExSync signal.
Free-run.
CCT+
Check to make sure that:
The exposure time is set no
lower than shown in Section
The frame period is set no
lower than shown in Section
Are the settings OK?
No
Correct
the
settings.
Binary
Commands
Did you set up free-run using the Exposure Time Control Mode
setting on the CCT+ or with binary commands?
Yes
Yes
Switch on the test image one.
Can the test image be seen?
Go to the
interfacing
troubleshooting
chart.
Replace the camera.
No
Yes
Check to make sure that the RS-644 serial connection is working OK. You can do
this by starting the Camera Configuration Tool Plus (CCT+). When you start the tool,
a startup graphic should appear and then a window that shows a list of parameter
settings should appear.
(If this is the first time that you are using the tool, you will see an empty window with
a drop down menu at the top which says “No port selected”. In this case, use the
drop down menu to select the RS-644 port that you want to use. RS-644 ports are
identified in the list by a port number and a *.dll library name. Once you select the
correct port, the list of parameter settings should appear.)
Did the list of parameter settings appear?
Go to the
RS-644
serial
communications
troubleshooting
chart.
No.
Yes
Содержание A400K
Страница 1: ...Basler A400k USER S MANUAL Document Number DA00062410 Release Date 27 September 2007 ...
Страница 4: ......
Страница 25: ...Camera Interface Basler A400k 2 9 DRAFT Figure 2 5 A402k Camera Frame Grabber Interface ...
Страница 26: ...Camera Interface 2 10 Basler A400k DRAFT Figure 2 6 A403k Camera Frame Grabber Interface ...
Страница 27: ...Camera Interface Basler A400k 2 11 DRAFT Figure 2 7 A404k Camera Frame Grabber Interface ...
Страница 52: ...Camera Interface 2 36 Basler A400k DRAFT ...
Страница 154: ...Configuring the Camera 4 54 Basler A400k DRAFT ...
Страница 168: ...Troubleshooting 6 10 Basler A400k DRAFT ...
Страница 172: ...Feedback iv Basler A400k DRAFT ...
Страница 176: ...Index viii Basler A400k DRAFT ...