- 47 -
Problem
Cause
Solution
8. The device is using
too much salt.
Too much water in the brine
tank.
Reduce the time of the brine
tank refilling with water, see
problem 9 „Too much water in
the brine tank”
Too frequent water
treatment.
Check the water hardness
degree and the set flow volume.
Incorrect programming.
Choose appropriate parameters
for the time of refilling with
water:
brine refill.
9. Too much water in
the brine tank.
Water level in the
brine tank is at the
overflow outlet.
The device does not take in
the brine.
See problem 10 „The device
does not take in the brine from
the brine tank”.
Clogged sewer drain.
Check the sewer drain hose.
Remember, that the sewer
drain pipe needs to have free
flow, clean if necessary.
Filling with water takes too
long.
Choose appropriate parame-
ters for the time of refilling with
water:
brine refill.
Power break during refilling
of the brine tank with water.
Check the power supply.
The water softening device
incorrectly connected.
Check the connections of the
device.
Resin tank leakage.
Check the resin tank for
leakage.
Control valve very slowly fills
the brine tank with water.
Call for service
Clogged DLFC flow regulator
Call for service
Water returns from the sewer
drainage system and through
the overflow outlet (at the
side of the water softening
device) flows to the brine
tank.
Hoses tightly connected with
the sewer drain. It is not
allowed.
Leaking hose connections.
Check connections.