- 43 -
6.6 Service instructions
Regeneration agent (brine) refill:
1. Remove the cover from the brine tank.
2. Add salt tablets to the brine tank (max. 10 kg).
Tip:
All the added tablets must be covered with water.
3. Close the cover.
CAUTION!
Never use the device without the regeneration agent.
Do not use the regeneration agent of the unknown origin or in the
powdered form.
Maintenance
Check the water softening system regularly.
Check the connections for leakages. In case of leakages of connections or sealing,
seal them or replace, if necessary.
Check the hoses for bending, bent hoses should be replaced.
Periodically, every 5 years at the maximus, replace the hoses, or more frequently if
necessary.
Do not use harsh chemicals, cleaning solutions or cleaning agents for cleaning.
Every 3 years the qualified specialist should carry out the maintenance of control
element and a technical inspection of the entire system.