During programming do not change the sequence of stages of the regeneration
process.
1. backwash (5 minutes)
2. regeneration agent (brine) rinse (50 minutes)
3. regeneration agent (brine) refill (30 sec.)
4. fast rinse ( 5 minutes)
These are proper settings for the production of the softened water. If they are
changed the device will not work properly.
System was pre-programmed to
A03
regeneration
mode
– smart, logic regeneration.
Based on the water consumption within the last 7 days, the system automatically
selects the regeneration time within the set time limit.
Fig. 2. Description of the control valve
1. Cold water inlet (flexible hose 3/4")
2. Outlet of the treated (softened) water (flexible hose 3/4")
3. Drain fitting (compression fitting 1/2")
4. Brine tank connection 3/8"
5. Flow meter
Fig. 2
Bypass adjustment
screw
Control panel
obsługi
Injector
Drain fitting
Cover
Brine tank
connection
Softened water outlet
Cold water inlet
Flow meter